Enzyme immunoassay of thyroxin-binding globulin in dried blood samples on filter paper.

نویسندگان

  • N Hata
  • M Ito
  • H Mizuta
  • O Nose
  • K Miyai
چکیده

A double-antibody enzyme immunoassay was developed for determination of thyroxin-binding globulin in dried blood samples on filter paper. The measurable concentration range of thyroxin-binding globulin in two 3-mm blood discs was 3.3 to 52 mg/L equivalent of serum (i.e., equivalent to the concentrations in known serum standards). Thyroxin-binding globulin in dried blood samples on filter paper was stable for at least four weeks when kept dry at -20 degrees C, 4 degrees C, or room temperature. The mean coefficients of variation were 6.6% (within assay) and 5.9% (between assays). The concentrations of thyroxin-binding globulin in dried blood samples determined by this method correlated well with those in serum determined by radioimmunoassay (r = 0.95) and by enzyme immunoassay (r = 0.96). This method is applicable for detecting cases of thyroxin-binding globulin deficiency and avoids the false-positive results for neonatal hypothyroidism obtained by measuring thyroxin.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radioimmunoassay of "free thyroxin" in dried blood spots on filter paper - preliminary observations on the effective differentiation of subjects with congenital hypothyroidism from those with subnormal thyroxin-binding globulin and normal subjects.

In this sensitive, simple method for measuring "free thyroxin" (FT4) in eluates of dried blood spots on filter paper by use of a radioimmunoassay kit (Amerlex Free T4 RIA), the measurable range of FT4 is 1.8 to 57 ng/L (equivalent to the concentration in serum), or 7 to 237 fg/tube. The mean coefficients of variation for within assay-within spots, within assay-between spots, and between assays ...

متن کامل

Chemiluminescence enzyme immunoassay for thyroxin with use of glucose oxidase and a bis(2,4,6-trichlorophenyl)oxalate-fluorescent dye system.

In this chemiluminescence enzyme immunoassay for thyroxin, glucose oxidase (EC 1.1.3.4) is the enzyme label and the bound and free fractions are separated by the double-antibody solid-phase technique. In the assay of enzyme activity, hydrogen peroxide generated from glucose substrate is measured by its chemiluminescence reaction with bis(2,4,6-trichlorophenyl)oxalate and 8-anilino-1-naphthalene...

متن کامل

New one-step enzyme immunoassay for free thyroxin.

This enzyme immunoassay for free thyroxin (FT4) involves simultaneous incubation of sample and thyroxin conjugated to horseradish peroxidase (EC 1.11.1.7) in antibody-coated tubes at room temperature. The test can be performed in 90 min. It is not influenced by variations in concentrations of thyroxin-binding globulin (TBG), thyroxin-binding prealbumin, or albumin. With increased concentrations...

متن کامل

Enzyme immunoassay of free thyroxin in serum.

We describe a double-antibody enzyme immunoassay for free thyroxin (FT4) in serum with use of beta-D-galactosidase conjugated to thyroxin. The method is uninfluenced by thyroxin-binding globulin or albumin. Values for FT4 so determined correlated well with those determined by radioimmunoassay (r = 0.98) and equilibrium dialysis (r = 0.89). The mean variability (CV) within and between assays was...

متن کامل

Two-site enzyme immunoassay for alpha-fetoprotein in dried-blood samples collected on filter paper.

This is a method for measuring alpha-fetoprotein (AFP) in eluates of dried-blood samples on filter paper by use of a simple, sensitive two-site enzyme immunoassay. The spot, 6 mm in diameter (equivalent to about 12 microL of whole blood), is incubated overnight with alkaline phosphatase conjugated to rabbit anti-AFP antibody in a tube containing a polystyrene bead coated with mouse monoclonal a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 29 7  شماره 

صفحات  -

تاریخ انتشار 1983