Analysis of the Effect of the CaCl2 Mass Fraction on the Efficiency of a Heat Pump Integrated Heat-Source Tower Using an Artificial Neural Network Model
نویسندگان
چکیده
An existing idle cooling tower can be reversibly used as a heat-source tower (HST) to drive a heat pump (HP) in cold seasons, with calcium chloride (CaCl2) aqueous solution commonly selected as the secondary working fluid in an indirect system due to its good thermo-physical properties. This study analyzed the effect of CaCl2 mass fraction on the effectiveness (ε) of a closed HST and the coefficient of performance (COP) of a HP heating system using an artificial neural network (ANN) technique. CaCl2 aqueous solutions with five different mass fractions, viz. 3%, 9%, 15%, 21%, and 27%, were chosen as the secondary working fluids for the HSTHP heating system. In order to collect enough measured data, extensive field tests were conducted on an experimental test rig in Changsha, China which experiences hot summer and cold winter weather. After back-propagation (BP) training, the three-layer (4-9-2) ANN model with a tangent sigmoid transfer function at the hidden layer and a linear transfer function at the output layer was developed for predicting the tower effectiveness and the COP of the HP under different inlet air dry-/wet-bulb temperatures, hot water inlet temperatures and CaCl2 mass fractions. The correlation coefficient (R), mean relative error (MRE) and root mean squared error (RMSE) were adopted to evaluate the prediction accuracy of the ANN model. The results showed that the R, MRE, and RMSE between the training values and the experimental values of ε (COP) were 0.995 (0.996), 2.09% (1.89%), and 0.005 (0.060), respectively, which indicated that the ANN model was reliable and robust in predicting the performance of the HP. The findings of this paper indicated that in order to guarantee normal operation of the system, the freezing point temperature of the CaCl2 aqueous solution should be sufficiently (3–5 K) below its lowest operating temperature or lower than the normal operating temperature by about 10 K. The tower effectiveness increased with increasing CaCl2 mass fraction from 0 to 27%, while the COP of the HP decreased. A tradeoff between the tower effectiveness and the COP of the HP should be considered to further determine the suitable mass fraction of CaCl2 aqueous solution for the HSTHP heating system. The outputs of this study are expected to provide guidelines for selecting brine with an appropriate mass fraction for a closed HSTHP heating system for actual applications, which would be a reasonable solution to improve the system performance.
منابع مشابه
Nanofluid Thermal Conductivity Prediction Model Based on Artificial Neural Network
Heat transfer fluids have inherently low thermal conductivity that greatly limits the heat exchange efficiency. While the effectiveness of extending surfaces and redesigning heat exchange equipments to increase the heat transfer rate has reached a limit, many research activities have been carried out attempting to improve the thermal transport properties of the fluids by adding more thermally c...
متن کاملEnergy Consumption and Heat Storage in a Solar Greenhouse: Artificial Neural Network Method
In this study, the performance of a solar greenhouse heating system equipped with a linear parabolic concentrator and a dual-purpose flat plate solar collector was investigated using the Artificial Neural Network (ANN) method. The heat required for the greenhouse at night hours was supplied by the heat stored in the storage tank by the solar system during the sunshine time and an auxiliary he...
متن کاملThermal performance enhancement of automobile radiator using water-CuO nanofluid: an experimental study
In the present paper, the effect of water-CuO nanofluid on the radiator heat transfer of an automobile, Peugeot 405 XU7 engine type is investigated experimentally. The experiments are carried out for the radiator water (water-ethylene glycol with a volume fraction of 80-20, respectively) as a base fluid and water-CuO nanofluid with the volume fraction of 0.5% and 1%. Sodium Dodecyl Sulfate (SDS...
متن کاملEffect of Ambient Condition on the Shower Cooling Tower in Four Type of Climates Condition
Water cooling by ambient takes place with two mechanisms of heat and mass transfer. Using packings at wet cooling towers has disadvantages such as obstruction, reduction of life expectancy and production of algae and fungi. In shower cooling towers types of towers packings are completely removed and water intake is in direct contact and heat transfer takes place in two ways of latent and sensib...
متن کاملUsing Neural Network to Determine Input Excesses, Output Shortfalls and Efficiency of Dmus in Russell Mode
Data Envelopment Analysis (DEA) has two fundamental approaches for assessing theefficiency with different characteristics; radial and non-radial models. This paper isconcerned the non-radial model of Russell which is a non linear model. Conventional DEAfor a large dataset with many inputs/outputs would require huge computer resources in termsof memory and CPU time. Artificial Neural Network (AN...
متن کامل