3D phase contrast MRI of cerebral blood flow and surface anatomy.
نویسندگان
چکیده
Noninvasive MR acquisition of blood flow and stationary tissue provides three-dimensional display of flow and of the vascular and brain surfaces. The calculated motion of a simulated bolus injection is derived from the measured velocity vector field and is animated to resemble cine angiography. Simulation of a bolus injection into the basilar artery of a healthy volunteer shows the blood flow into the posterior cerebral arteries.
منابع مشابه
Improved assessment of aortic 3D blood flow with combined k-t accelerated 3D CINE bSSFP & 4D flow MRI
Background To determine hemodynamic parameters from 4D flow MRI, vessel boundaries are typically depicted by calculating a 3D phase contrast MR angiogram (PC-MRA) from 4D flow magnitude and flow images. However, this approach is limited by 1) low blood-tissue contrast of the magnitude images and 2) velocity weighting of PC-MRA may not fully depict areas of slow or swirling (vortex) flow. As a r...
متن کاملSpontaneous Intracranial Hypotension Plus Cerebral Venous Thrombosis: A Case Report Study
This is a case study of a 34-year-old woman who was admitted to hospital with a history of severe orthostatic headache. She was diagnosed as having spontaneous intracranial hypotension (SIH) by undetectable cerebrospinal fluid (CSF) pressure at lumbar puncture, and with evidence of diffuse dural enhancement of the brain detected by magnetic resonance imaging (MRI). However, the contrast-enhance...
متن کاملThree-dimensional printing of anatomically accurate, patient specific intracranial aneurysm models.
OBJECTIVE To develop and validate a method for creating realistic, patient specific replicas of cerebral aneurysms by means of fused deposition modeling. METHODS The luminal boundaries of 10 cerebral aneurysms, together with adjacent proximal and distal sections of the parent artery, were segmented based on DSA images, and corresponding virtual three-dimensional (3D) surface reconstructions w...
متن کاملFeasibility of whole-brain dynamic contrast enhanced (DCE) MRI using 3D k-t PCA
INTRODUCTION: Quantification of cerebral blood flow using dynamic contrast enhanced (DCE) MRI [1] has several advantages over conventional dynamic susceptibility contrast (DSC) MRI [2]. Most importantly, DCE-MRI avoids the inherent susceptibility artifacts of DSC-MRI, thus allowing for more reliable measurement of the arterial input function (AIF) and quantification of blood brain barrier leaka...
متن کاملWall shear stress vectors derived from 3D PC-MRI at increasing resolutions in an intracranial aneurysm phantom
Background Wall shear stress (WSS) is the friction force that blood flow exerts on the vessel wall. It is thought to affect the function of endothelial cells and the development of atherosclerosis and aneurysms. A promising technique to measure blood flow is three-dimensional phase contrast MRI (3D PC-MRI). Due to limited spatial resolution and SNR, estimating WSS from time-resolved 3D PC-MRI i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of computer assisted tomography
دوره 17 2 شماره
صفحات -
تاریخ انتشار 1993