Reduced field of view MRI with rapid, B1-robust outer volume suppression.
نویسندگان
چکیده
MRI scans are inefficient when the size of the anatomy under investigation is small relative to the subject's full extent. The field of view must be expanded, and acquisition times accordingly prolonged. Shorter scans are feasible with reduced field of view imaging (rFOV) using outer volume suppression (OVS), a magnetization preparation sequence that attenuates signal outside a region of interest (ROI). This work presents a new OVS sequence with a cylindrical ROI, short duration, and improved tolerance for B(1)+ inhomogeneity. The sequence consists of a nonselective adiabatic tipdown pulse, which provides B(1)+-robust signal suppression, and a fast 2D spiral cylindrical tipback pulse. Analysis of the Bloch equations with transverse initial magnetization reveals a conjugate symmetric constraint for tipback pulses with small flip angles. This property is exploited to achieve two-shot performance from the single-shot tipback pulse. The OVS sequence is validated in phantoms and in vivo with multislice spiral imaging at 3 T. The relative signal-to-noise ratio efficiency of the proposed sequence was 98% in a phantom and 75-90% in vivo. The effectiveness is demonstrated with cardiovascular rFOV imaging, which exhibits improved resolution and reduced artifacts compared to conventional, full field of view imaging.
منابع مشابه
Outer Volume Suppression (OVS) for Single Voxel Spectroscopy (SVS) at 7 Tesla using interleaved B1 shim settings
Introduction High-field magnetic resonance spectroscopy (MRS) has the potential to provide enhanced neurochemical information based on increased sensitivity and higher spectral resolution. However, problems arising in high-field magnetic resonance imaging (MRI), such as more pronounced B0 and B1 inhomogeneities, may decrease spectral resolution and ultimately the quantification accuracy. A mult...
متن کاملZoomed functional imaging in the human brain at 7 Tesla with simultaneous high spatial and high temporal resolution.
Functional neuroimaging in the human brain using noninvasive magnetic resonance methods has the potential of providing highly resolved maps of neuronal activation. Decreasing the voxel size and obtaining simultaneously high temporal resolution is a major challenge and is mainly limited by sensitivity. Here, signal-to-noise gains at high magnetic fields (7 Tesla) and an optimized surface coil se...
متن کاملReduced field-of-view diffusion-weighted imaging of the brain at 7 T.
Ventral and rostral regions of the brain are of emerging importance for the MRI characterization of early dementia, traumatic brain injury and epilepsy. Unfortunately, standard single-shot echo planar diffusion-weighted imaging of these regions at high fields is contaminated by severe imaging artifacts in the vicinity of air-tissue interfaces. To mitigate these artifacts and improve visualizati...
متن کاملActive Vibration Suppression of a Nonlinear Flexible Spacecraft
In this article, the issue of attitude control and active vibration suppression of a nonlinear flexible spacecraft is assessed through piezoelectric patches as actuator and sensors. Two controller loops are applied: the inner loop, to make the panel vibration damped through piezoelectric patches; and the outer loop, to perform spacecraft maneuver using the reaction wheel acting on the hub. An o...
متن کاملSystematic Comparison of Quantitative T1 Mapping Methods at 7 T High Field
INTRODUCTION Quantitative MRI offers many advantages in diagnosis and also in longitudinal or cross-sectional studies. The measurement of T1 is of particular interest. However, many T1 quantification methods rely on accurate knowledge of B1 which varies significantly over the field of view (FOV) at high magnetic field. TESSA as a new method for rapid and simultaneous mapping of T1 and B1 has be...