Radiation Safety Considerations for the TPS Accelerators

نویسندگان

  • R. J. Sheu
  • J. Liu
  • J. P. Wang
چکیده

This study investigates the characteristics of prompt radiation field and some issues of induced activities due to the operation of the Taiwan Photon Source (TPS). Starting from assumed beam loss scenarios and using the FLUKA Monte Carlo simulations, energy spectra and dose distributions of the prompt radiation field for its shielding design were studied. Radiation environment around the penetrations on shielding walls were also taken into account. As to the impact of induced radioactivity, we also used the FLUKA to evaluate the residual activities, remanent dose rates, and their time behaviors for various target materials and cooling times based on conservative irradiation conditions. The paper summarizes the present status of the radiation safety evaluation for the TPS accelerators.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiation Safety Analysis for the TPS Accelerators

Taiwan Photon Source (TPS) will be a 3 GeV light source with a circumference of 518.4 m and operating fully at 400 mA in top-up mode, aiming to provide synchrotron light with extremely high brilliance and low emittance. Significant amount of radiation will be produced due to the loss of such high-energy electrons and result in radiation safety concerns. The design objective of radiation safety ...

متن کامل

Validation of treatment planning system using simulation PRIMO code.

Introduction: In radiation therapy, in order to double-check the dosimetric results of the main treatment planning system (TPS), a distinct TPS, with few capacitances in terms of contouring and a variety of dose calculation algorithms is used. This system has the capability to double check the planification and the accurate prediction of dose distribution in order to be ensured...

متن کامل

Comparing experimental assessment of the peripheral dose outside the applicator in electron beams of ELEKTA with Treatment planning system

Introduction: The use of electrons in the electron therapy to destroy tumoral tissue is dedicated significant contribution of different methods of radiation therapy. Scattered radiation due to exited electrons of the applicator affect the dose out of the field in the patient's normal tissue. The aim of this study is to determine the peripheral dose outside the applicator in the...

متن کامل

Benchmark Calculations of Neutron Production and Induced Radioactivity for a Proton and a Carbon Therapy Accelerator*

This study intends to predict the scope of neutron production and induced radioactivity for two therapy accelerators in Taiwan: 235 MeV proton and 400 MeV/A carbon ion accelerators. For radiation safety concern, much effort has been put into associated benchmark calculations to ensure the quality of predictions. Two Monte Carlo codes FLUKA and MCNPX were applied to calculate the neutron yield f...

متن کامل

The Quality Control of Intensity Modulated Radiation Therapy (IMRT) for ONCOR Siemens Linear Accelerators Using Film Dosimetry

Introduction Intensity Modulated Radiation Therapy (IMRT) has made a significant progress in radiation therapy centers in recent years. In this method, each radiation beam is divided into many subfields that create a field with a modulated intensity. Considering the complexity of this method, the quality control for IMRT is a topic of interest for researchers. This article is about the various ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010