Interaural Time-Difference Discrimination as a Measure of Place of Stimulation for Cochlear-Implant Users With Single-Sided Deafness.

نویسندگان

  • Joshua G W Bernstein
  • Olga A Stakhovskaya
  • Gerald I Schuchman
  • Kenneth K Jensen
  • Matthew J Goupell
چکیده

Current clinical practice in programming a cochlear implant (CI) for individuals with single-sided deafness (SSD) is to maximize the transmission of speech information via the implant, with the implicit assumption that this will also result in improved spatial-hearing abilities. However, binaural sensitivity is reduced by interaural place-of-stimulation mismatch, a likely occurrence with a standard CI frequency-to-electrode allocation table (FAT). As a step toward reducing interaural mismatch, this study investigated whether a test of interaural-time-difference (ITD) discrimination could be used to estimate the acoustic frequency yielding the best place match for a given CI electrode. ITD-discrimination performance was measured by presenting 300-ms bursts of 100-pulses-per-second electrical pulse trains to a single CI electrode and band-limited pulse trains with variable carrier frequencies to the acoustic ear. Listeners discriminated between two reference intervals (four bursts each with constant ITD) and a moving target interval (four bursts with variable ITD). For 17 out of the 26 electrodes tested across eight listeners, the function describing the relationship between ITD-discrimination performance and carrier frequency had a discernable peak where listeners achieved 70% to 100% performance. On average, this peak occurred 1.15 octaves above the CI manufacturer's default FAT. ITD discrimination shows promise as a method of estimating the cochlear place of stimulation for a given electrode, thereby providing information to optimize the FAT for SSD-CI listeners.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of age at onset of deafness on binaural sensitivity in electric hearing in humans.

Sensitivity to binaural cues was studied in 11 bilateral cochlear implant users, all of whom received both of their cochlear implants as adults, but who varied in the age at onset of deafness, from pre-lingual to childhood-onset to adult-onset. Sensitivity to interaural timing difference (ITD) and interaural level difference (ILD) cues was measured at basal, middle, and apical pitch-matched pla...

متن کامل

Interaural envelope correlation change discrimination in bilateral cochlear implantees: effects of mismatch, centering, and onset of deafness.

Bilateral cochlear implant (CI) listeners can perform binaural tasks, but they are typically worse than normal-hearing (NH) listeners. To understand why this difference occurs and the mechanisms involved in processing dynamic binaural differences, interaural envelope correlation change discrimination sensitivity was measured in real and simulated CI users. In experiment 1, 11 CI (eight late dea...

متن کامل

Monaural Congenital Deafness Affects Aural Dominance and Degrades Binaural Processing

Cortical development extensively depends on sensory experience. Effects of congenital monaural and binaural deafness on cortical aural dominance and representation of binaural cues were investigated in the present study. We used an animal model that precisely mimics the clinical scenario of unilateral cochlear implantation in an individual with single-sided congenital deafness. Multiunit respon...

متن کامل

Lateralization of interaural timing differences with multi-electrode stimulation in bilateral cochlear-implant users.

Bilateral cochlear implant (BiCI) users have shown variability in interaural time difference (ITD) sensitivity at different places along the cochlea. This paper investigates perception of multi-electrode binaural stimulation to determine if auditory object formation (AOF) and lateralization are affected by variability in ITD sensitivity when a complex sound is encoded with multi-channel process...

متن کامل

The use of interaural time and level difference cues by bilateral cochlear implant users.

While considerable evidence suggests that bilateral cochlear implant (CI) users' sound localization abilities rely primarily on interaural level difference (ILD) cues, and only secondarily, if at all, on interaural time difference (ITD) cues, this evidence has largely been indirect. This study used head-related transfer functions (HRTFs) to independently manipulate ITD and ILD cues and directly...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Trends in hearing

دوره 22  شماره 

صفحات  -

تاریخ انتشار 2018