Response to letter regarding article, "Flow-gradient patterns in severe aortic stenosis with preserved ejection fraction: clinical characteristics and predictors of survival".

نویسندگان

  • Mackram F Eleid
  • Paul Sorajja
  • Hector I Michelena
  • Joseph F Malouf
  • Chrisopher G Scott
  • Patricia A Pellikka
چکیده

BACKGROUND Among patients with severe aortic stenosis (AS) and preserved ejection fraction, those with low gradient (LG) and reduced stroke volume may have an adverse prognosis. We investigated the prognostic impact of stroke volume using the recently proposed flow-gradient classification. METHODS AND RESULTS We examined 1704 consecutive patients with severe AS (aortic valve area <1.0 cm(2)) and preserved ejection fraction (≥50%) using 2-dimensional and Doppler echocardiography. Patients were stratified by stroke volume index (<35 mL/m(2) [low flow, LF] versus ≥35 mL/m(2) [normal flow, NF]) and aortic gradient (<40 mm Hg [LG] versus ≥40 mm Hg [high gradient, HG]) into 4 groups: NF/HG, NF/LG, LF/HG, and LF/LG. NF/LG (n=352, 21%), was associated with favorable survival with medical management (2-year estimate, 82% versus 67% in NF/HG; P<0.0001). LF/LG severe AS (n=53, 3%) was characterized by lower ejection fraction, more prevalent atrial fibrillation and heart failure, reduced arterial compliance, and reduced survival (2-year estimate, 60% versus 82% in NF/HG; P<0.001). In multivariable analysis, the LF/LG pattern was the strongest predictor of mortality (hazard ratio, 3.26; 95% confidence interval, 1.71-6.22; P<0.001 versus NF/LG). Aortic valve replacement was associated with a 69% mortality reduction (hazard ratio, 0.31; 95% confidence interval, 0.25-0.39; P<0.0001) in LF/LG and NF/HG, with no survival benefit associated with aortic valve replacement in NF/LG and LF/HG. CONCLUSIONS NF/LG severe AS with preserved ejection fraction exhibits favorable survival with medical management, and the impact of aortic valve replacement on survival was neutral. LF/LG severe AS is characterized by a high prevalence of atrial fibrillation, heart failure, and reduced survival, and aortic valve replacement was associated with improved survival. These findings have implications for the evaluation and subsequent management of AS severity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bicuspid aortic valve stenosis with successful transfemoral transcatheter aortic valve replacement (TAVI) using the Sapien 3 valve.

catheterization study. Circulation 2013;128:S235–S242. 18. Dumesnil JG, Pibarot P. Letter by Dumesnil and Pibarot regarding article, ‘Outcome of patients with low-gradient ‘severe’ aortic stenosis and preserved ejection fraction’. Circulation 2011;124:e360. 19. Cueff C, Serfaty JM, Cimadevilla C, Laissy JP, Himbert D, Tubach F, Duval X, Iung B, Enriquez-Sarano M, Vahanian A, Messika-Zeitoun D. ...

متن کامل

Flow-Gradient Patterns in Severe Aortic Stenosis with Preserved Ejection Fraction: Clinical Characteristics and Predictors of Survival

Ad Ad Addr dr dres es ess s s fo fo for r r Co Co Corr rr rres es espo po pond nd nden en ence ce ce: : : Abstract: Background—Among patients with severe aortic stenosis (AS) and preserved ejection fraction

متن کامل

Letter by Poullis and Warwick regarding article, "Paradoxical low-flow, low-gradient severe aortic stenosis despite preserved ejection fraction is associated with higher afterload and reduced survival".

“Paradoxical Low-Flow, Low-Gradient Severe Aortic Stenosis Despite Preserved Ejection Fraction Is Associated With Higher Afterload and Reduced Survival” To the Editor: In their article, Hachicha et al1 raise a number of key points that merit further questioning. Despite the direct relevance of their findings to everyday clinical practice, it is our opinion that their use of the terms paradoxica...

متن کامل

Paradoxical low flow and/or low gradient severe aortic stenosis despite preserved left ventricular ejection fraction: implications for diagnosis and treatment

Paradoxical low flow, low gradient, severe aortic stenosis (AS) despite preserved ejection fraction is a recently described clinical entity whereby patients with severe AS on the basis of aortic valve area have a lower than expected gradient in relation to generally accepted values. This mode of presentation of severe AS is relatively frequent (up to 35% of cases) and such patients have a clust...

متن کامل

Paradoxical low-flow, low-gradient severe aortic stenosis despite preserved ejection fraction is associated with higher afterload and reduced survival.

BACKGROUND Recent studies and current clinical observations suggest that some patients with severe aortic stenosis on the basis of aortic valve area may paradoxically have a relatively low gradient despite the presence of a preserved left ventricular (LV) ejection fraction. The objective of the present study was to document the prevalence, potential mechanisms, and clinical relevance of this ph...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 128 16  شماره 

صفحات  -

تاریخ انتشار 2013