Late Sac Rupture due to a Type IV Endoleak after Previous Endovascular Aortic Aneurysm Repair: A Case Report

نویسندگان

  • Konstantinos Filis
  • Constantinos Zarmakoupis
  • Georgios Karantzikos
  • Frangiska Sigala
  • Gerasimos Bazigos
  • George Galyfos
چکیده

Type IV endoleaks have been identified as endoleaks of low flow, and rupture risk has been estimated to be minimal in literature. Therefore, conservative treatment has been recommended in most cases. We are presenting a rare case of late rupture due to type IV endoleak that was treated with open repair applying a novel surgical technique.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transradial approach for the endovascular treatment of type I endoleak after aortic aneurysm repair: a case report

BACKGROUND Endovascular repair of aortic aneurysms (EVAR) is obtained through the positioning of an aortic stent-graft, which excludes the aneurysmatic dilation. Type I endoleak is the most common complication, and it is caused by an incompetent proximal or distal attachment site, causing the separation between the stent-graft and the native arterial wall, and in turn creating direct communicat...

متن کامل

Late Type 3b Endoleak Mimicking Type 2 Endoleak after Endovascular Aortic Aneurysm Repair

Endovascular abdominal aortic aneurysm (AAA) repair has been widely used for the treatment of AAA as a safe and efficient method, but endoleaks causing persistent expansion of aneurysm sac may cause aneurysmal rupture and death. Type 3 endoleak is rare but a predominant cause of late rupture. Type 3b endoleak can be misdiagnosed as type 2 endoleak, which is more frequent. Here we report two cas...

متن کامل

Late type IIIb endoleak after endovascular aneurysm repair: case report and review of the literature.

PURPOSE To report a case of type IIIb endoleak developed six years after endovascular abdominal aortic aneurysm repair (EVAR). CASE REPORT A 75-year-old man underwent successful Talent™ stent-graft positioning to treat a 53 mm abdominal aortic aneurysm. Subsequently the patient did well and yearly routine control computerized tomography (CT) was unremarkable. Six years later the patient sudde...

متن کامل

Aneurysm growth after late conversion of thoracic endovascular aortic repair

A 69-year-old man underwent thoracic endovascular aortic repair of a descending aortic aneurysm. Three years later, he developed impending rupture due to aneurysmal expansion that included the proximal landing zone. Urgent open surgery was performed via lateral thoracotomy, and a Dacron graft was sewn to the previous stent graft distally with Teflon felt reinforcement. Postoperatively, four seq...

متن کامل

Late aneurysm rupture after endovascular abdominal aneurysm repair.

OBJECTIVES The goal of endovascular repair is to protect the patient from aneurysm rupture. Careful surveillance should be performed postoperatively in order to select patients with aneurysm growth and, therefore, the highest rupture risk. The aim of the study was to present our experience with aneurysm rupture in long-term follow-up after endovascular abdominal aneurysm repair. METHODS Betwe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2017