Mechanical ventilation with positive end-expiratory pressure in critically ill patients: comparison of CW-Doppler ultrasound cardiac output monitoring (USCOM) and thermodilution (PiCCO).
نویسندگان
چکیده
BACKGROUND Aggressive mechanical ventilation can markedly and unpredictably affect cardiac function. The fall in cardiac output (CO) is due to a reduction in left ventricular stroke volume (SV). The aim of the present pilot study was to assess the effects of different positive end-expiratory pressure (PEEP) levels on circulatory function and to compare them with continuous wave (CW)-Doppler ultrasound cardiac output monitoring (USCOM) and a thermodilution-based haemodynamic monitoring system (PiCCO). METHODS Twenty mechanically ventilated (PEEP < or = 10 mbar) adult patients (female n = 6, male n = 14, mean age 62 years, mean SAPS II-score 48.5), the majority with pneumonia and septic shock) were followed with USCOM and PiCCO at stepwise increased PEEP-levels from 0-10 mbar (1 mbar steps). The changes in CO/SV were recorded. RESULTS With both methods, an increase of PEEP resulted in a decrease of SV and CO. Although the absolute decrease was consistently higher by USCOM, the changes of the parameters were qualitatively comparable. CO fell from 8.83 L/min (+/- 2.39) by 0.4 L/min to 8.49 L/min (+/- 2.48) with PiCCO and from 9.3 L/min (+/- 3.43) by 1.0 L/min to 8.3 L/min (+/- 3.2) with USCOM. The median CO/SV fell by 4.5%/5.2% with PiCCO and 10.8%/9% with USCOM, respectively. Correlation of CO values with the two methods by Bland-Altman yielded comparable results (mean percentage error at PEEP 0 mbar 13%, PEEP 10 mbar 18%). An adequate flow signal with USCOM was achieved in all patients. CONCLUSIONS A significant influence of mechanical ventilation with PEEP on haemodynamic parameters was evident both with USCOM and PiCCO. While thermodilution methods like PiCCO are well established but time-consuming and invasive, CW-Doppler based USCOM constitutes an important tool for easy, rapid and reliable diagnosis and haemodynamic monitoring of critically ill patients.
منابع مشابه
Cardiac Output Measurements in Septic Patients: Comparing the Accuracy of USCOM to PiCCO
USCOM is an ultrasound-based method which has been accepted for noninvasive hemodynamic monitoring in various clinical conditions (USCOM, Ultrasonic cardiac output monitoring). The present study aimed at comparing the accuracy of the USCOM device with that of the thermodilution technique in patients with septicemia. We conducted a prospective observational study in a medical but noncardiologica...
متن کاملClinical evaluation of USCOM ultrasonic cardiac output monitor in cardiac surgical patients in intensive care unit.
BACKGROUND The USCOM ultrasonic cardiac output monitor (USCOM Pty Ltd, Coffs Harbour, NSW, Australia) is a non-invasive device that determines cardiac output by continuous-wave Doppler ultrasound. The aim of this study was to evaluate the accuracy of the USCOM device compared with the thermodilution technique in intensive care patients who had just undergone cardiac surgery. METHODS We conduc...
متن کاملComparison of the accuracy of transpulmonary thermodilution measurement using indicators of different temperatures.
Transpulmonary thermodilution measurement is a convenient method for hemodynamic monitoring. However, the previously reported indicator temperature was not consistent. This study aimed to compare the accuracy of Pulse index Continuous Cardiac Output (PiCCO) monitoring using indicators of different temperatures. A total of 104 critically ill patients received PiCCO monitoring using indicators of...
متن کاملPulmonary artery catheter versus pulse contour analysis: a prospective epidemiological study
INTRODUCTION The choice of invasive systemic haemodynamic monitoring in critically ill patients remains controversial as no multicentre comparative clinical data exist. Accordingly, we sought to study and compare the features and outcomes of patients who receive haemodynamic monitoring with either the pulmonary artery catheter (PAC) or pulse contour cardiac output (PiCCO) technology. METHODS ...
متن کاملComparison of the USCOM ultrasound cardiac output monitor with pulmonary artery catheter thermodilution in patients undergoing liver transplantation.
The aim of the study was to compare the standard technique of cardiac output determination by pulmonary artery catheter thermodilution (PAC-TD) with a noninvasive ultrasound Doppler monitor (USCOM Pty., Ltd., Coffs Harbour, Australia) in surgery for liver transplantation. We wished to determine if the degree of accuracy would allow the ultrasound cardiac output monitor (USCOM) to be used as an ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta cardiologica
دوره 67 2 شماره
صفحات -
تاریخ انتشار 2012