The rate of wear of second-generation highly crosslinked polyethylene liners five years post-operatively does not increase if large femoral heads are used.
نویسندگان
چکیده
AIMS The increased in vivo resistance to wear of highly crosslinked polyethylene (HXLPE) in total hip arthroplasty (THA) has led to an increased use of larger articulations which have been shown to reduce the incidence of early dislocation. To date, there are few reports of the wear of larger articulations using second generation HXLPE liners. Our prospective cohort study measured the bedding-in and early wear of large (36 mm and 40 mm diameter) articulations involving a second generation X3 HXLPE liner and compared our findings with previous clinical and in vitro studies of the same material. PATIENTS AND METHODS The proximal penetration of the femoral head five years post-operatively was measured for 15 patients using radiostereometric analysis (RSA). RESULTS The median proximal bedding-in within the first post-operative year was 0.022 mm (interquartile range (IQR) -0.050 to 0.091). The median proximal rate of wear between one and five years was -0.004 mm/year (IQR -0.021 to 0.022). The rates of proximal, medial, 2D or 3D wear between one and five years post-operatively of the X3 HXLPE liner did not increase with larger articulations compared with our previous study of 32 mm articulations. CONCLUSION Although reassuring, the use of larger articulations requires continued monitoring to determine whether the low wear observed in the short-term continues to the mid- to long-term. Cite this article: Bone Joint J 2016;98-B:1604-10.
منابع مشابه
The Effect of In Vivo Damage of Oxinium Femoral heads on the Wear of Highly Cross-linked Polyethylene
Bragdon, C.R; Wannomae, K. K.; Lozynsky, A.; Micheli, B.; Malchau, H. Harris Orthopaedic Biomechanics and Biomaterials Laboratory, Massachusetts General Hospital, Boston, MA 02114 Senior author [email protected] INTRODUCTION: Oxidized zirconium (OxiniumTM) is a bearing surface introduced for use in THA to minimize wear in vivo. Oxinium femoral heads are manufactured by oxidizing wrought Zr-...
متن کامل‘severe’ Wear Challenge to 36 Mm Mechanically Enhanced Crosslinked Polyethylene Hip Cups
Introduction Recent studies have shown that sequential irradiation/annealing processes improves the wear performance and oxidation resistance of crosslinked polyethylene, while maintaining mechanical properties [1,2]. Although these early results showed great promise for mechanically enhanced XLPE, we still know little about the variables that can lead to high-wear, particularly surface roughne...
متن کاملWear of a sequentially annealed polyethylene acetabular liner
BACKGROUND AND PURPOSE We previously reported on a randomized controlled trial (RCT) that examined the effect of adding tobramycin to bone cement after femoral stem migration. The present study examined femoral head penetration into both conventional and highly crosslinked polyethylene acetabular liners in the same group of RCT patients, with a minimum of 5 years of postoperative follow-up. P...
متن کاملResults of Total Hip Arthroplasty with 36-mm Metallic Femoral Heads on 1st Generation Highly Cross Linked Polyethylene as a Bearing Surface in Less than Forty Year-old Patients: Minimum Ten-year Results
Purpose We evaluated long-term clinical and radiographic results in patients underwent primary total hip arthroplasty (THA) using 36-mm metallic femoral head and 1st generation highly cross-linked polyethylene among patients aged 40 years and less, with minimum 10 years follow-up. Materials and Methods We retrospectively reviewed 20 hips underwent primary THA by one hip surgeon using 36-mm fe...
متن کاملRetrieval analyses of highly cross-linked polyethylene acetabular liners four and five years after implantation.
Two Durasul highly crosslinked polyethylene liners were exchanged during revision surgery four and five years after implantation, respectively. The retrieved liners were evaluated macroscopically and surface analysis was performed using optical and electron microscopy. A sample of each liner was used to determine the oxidation of the material by Fourier transform infrared spectroscopy. Samples ...