An improved ultrafiltration method for determining free testosterone in serum.
نویسندگان
چکیده
In this method, we use the Amicon MPS-1 centrifugal ultrafiltration device and the YMB membrane in measuring free testosterone in serum. Two independent assays are combined: total testosterone and the ultrafiltrable fraction of added [3H]testosterone. The unbound fraction is determined in 0.15-0.5 mL ultrafiltrates of 0.6 to 1 mL of variably diluted serum that has been equilibrated with [3H]testosterone at 37 degrees C. The assay is rapid (less than 1 h), practicable (requires 0.6 mL of serum), and reproducible (CV 3.2% within assay, 3.9% between assays). Accuracy was evaluated as the fraction of free testosterone in the ultrafiltrate of dialyzed serum vs that in a prior dialysate; they were the same confirming the validity of the free testosterone measurement. Samples from ostensibly healthy men and women and from hirsute and pregnant women gave results that agreed with those obtained by equilibrium dialysis. Total testosterone concentrations for normal and hirsute women showed considerable overlap, but data on free testosterone concentrations in these populations were better resolved.
منابع مشابه
مقایسهی تستوسترون آزاد بزاق با تستوسترون آزاد سرم در بیماران مبتلا به هیرسوتیسم و گروه شاهد
Background and Aim: Hirsutism is defined as male pattern hair growth in females which affects 10% of women. Our aim was to compare free salivary and free serum testosterone levels in women with hirsutism and healthy controls.Methods: This study was a case-control study in which 30 hirsute women in child bearing age were recruited and compared with 10 healthy controls. For each patient, a questi...
متن کاملAn improved ultrafiltration method for free thyroxine and triiodothyronine in serum.
We describe an ultrafiltration technique for rapidly and directly determining free triiodothyronine or free thyroxine, or both. After equilibrating serum at 37 degrees C with purified tracer of high specific activity, we placed 0.15 mL of serum in 2.8 mL of phosphate buffer (0.1 mol/L, pH 7.4) in the ultrafiltration cell and obtained successive 0.2- and 0.6-mL fractions of protein-free ultrafil...
متن کاملFree serum cortisol: quantification applying equilibrium dialysis or ultrafiltration and an automated immunoassay system.
BACKGROUND Quantification of bioactive, free serum cortisol concentrations can characterize adrenocortical function more appropriately compared to total serum cortisol measurement. Ultrafiltration or equilibrium dialysis of serum samples allow direct measurement of free serum cortisol concentrations but respective methods have poorly been validated so far. The aim of our study was to investigat...
متن کاملP-67: Nano-Selenium Protects Cisplatin-Induced Spermatotoxicty and Chromatin Abnormality Associated with Free Radicals Toxic Stress
Background: Cisplatin (CIS), an anticancer alkylating agent, induces DNA adducts and effectively cross links the DNA strands and so affects spermatozoa as a male reproductive tract toxicant. Materials and Methods: The present study investigated the cellular/biochemical mechanisms underlying possible protective effect of selenium nano-particles (Nano-Se) as an established strong antioxidant with...
متن کاملThe "ultra-free" ultrafiltration technique compared with equilibrium dialysis for determination of unbound thiopental concentrations in serum.
We compare a new ultrafiltration technique, involving a unique Millipore membrane, with the classical method of equilibrium dialysis for determining the fraction of thiopental not bound to serum proteins. This fraction, as determined by equilibrium dialysis at 37 degrees C, ranged between 12 and 16% for total concentrations at 50 microgram/L to 10 mg/L of serum. In contrast, ultrafiltration at ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 28 11 شماره
صفحات -
تاریخ انتشار 1982