Use of an electronic barcode system for patient identification during blood transfusion: 3-year experience in a regional hospital.
نویسندگان
چکیده
OBJECTIVE To evaluate the use of an electronic barcode system for patient identification during blood transfusion. DESIGN Retrospective study. SETTING Regional hospital, Hong Kong. PATIENTS For all patients requiring blood transfusion between May 1999 and April 2002, with the exception of patients in the psychiatric wards and the accident and emergency department, a portable, hand-held scan-and-print electronic device was used to verify and document patients' identity at two critical points of transfusion: blood sampling for the compatibility test and blood administration. MAIN OUTCOME MEASURES Scope of use of the electronic device, cost, effectiveness, staff compliance, problems and solution for improvement. RESULTS In the first 3 years of hospital-wide use of the new device, no incidents of blood transfusion to wrong patients, or wrong labelling of blood samples, occurred with 41,00 blood sampling procedures and administration of 27 000 units of blood. Blood sampling took 6 minutes to complete with the use of the electronic device-similar to that taken by the conventional second-checker system. Among hospital staff, the compliance rate of using the new device approached 90%. Battery problems occurred in 12% of episodes of use of the device. CONCLUSIONS The electronic barcode system was effective in reducing human error related to bedside transfusion procedures. The future goal is to tailor-make a more efficient device with additional functions.
منابع مشابه
Identification of First Patient with Rh null Phenotype in Southeast Iran
Background and Aims: Rhnull, with an estimated incidence of one per 6,000,000 individuals, is an extremely rare disorder with an autosomal recessive pattern of inheritance that is more common in societies with a high rate of consanguinity. Materials and Methods: In this study, we report the first case with Rhnull, a blood group phenotype in southeast Iran, which was diagnosed during pretransf...
متن کاملA case report of heterogeneous blood transfusion in the operating room
Introduction: Mismatched-blood transfusions in the ABO-system may lead to severe of complications such as intravascular hemolysis. Case report: A 49-year-old man suffering from a right lower limb injury due to accident was admitted to hospital. Vital signs were normal. X-ray showed a femoral neck fracture. Before surgery, all of lab tests were in normal values and B+ blood- group was reported. ...
متن کاملElectronic Pre-Transfusion Check at the Bedside: Experience in a University Hospital
of the guidelines Background: JSTMCT Working Party on hemovigilance and safety management of blood transfusion issued the first version of guidelines for the electronic pre-transfusion check for blood administration at the bedside [33]. The current guidelines cover issues concerning: a) Pre-transfusion check procedures at the bedside b) Requirements for the electronic pre-transfusion check at t...
متن کاملMaximum surgical blood ordering schedule improves blood utilization in elective surgeries :An experience in Faghihi hospital, Shiraz, Iran
Abstract Background and Objectives Over-ordering of blood before operation can cause unnecessary cross matches, blood bank staff overload, blood unit wastages due to outdating, and increase hospital costs. So, we aimed to survey the efficacy of MSBOS on blood utilization in Faghihi Hospital, Shiraz, Iran. Materials and Methods This cross sectional study was conducted over a three month per...
متن کاملGallium‐68 DOTATATE Production with Automated PET Radiopharmaceutical Synthesis System: A Three Year Experience
Objective(s): Gallium‐68 (Ga‐68) is an ideal research and hospital‐based PET radioisotope. Currently, the main form of Ga‐68 radiopharmaceutical that is being synthesised in‐house is Ga‐68 conjugated with DOTA based derivatives. The development of automated synthesis systems has increased the reliability, reproducibility and safety of radiopharmaceutical productions. Here we report on our three...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Hong Kong medical journal = Xianggang yi xue za zhi
دوره 10 3 شماره
صفحات -
تاریخ انتشار 2004