Noninvasive pulse pressure variation and stroke volume variation to predict fluid responsiveness at multiple thresholds: a prospective observational study
نویسندگان
چکیده
BACKGROUND Pulse pressure variation (PPV) and stroke volume variation (SVV) are dynamic preload variables that can be measured noninvasively to assess fluid responsiveness (FR) in anesthetized patients with mechanical ventilation. Few studies have examined the effectiveness of predicting FR according to the definition of FR, and assessment of inconclusive values of PPV and SVV around the cut-off value (the "grey zone") might improve individual FR prediction. We explored the ability of noninvasive volume clamp derived measurements of PPV and SVV to predict FR using the grey zone approach, and we assessed the influence of multiple thresholds on the predictive ability of the numerical definition of FR. METHODS Ninety patients undergoing general surgery were included in this prospective observational study and received a 500 mL fluid bolus as deemed clinically required by the attending anesthesiologist. A minimal relative increase in stroke volume index (↑SVI) was used to define FR with different thresholds from 10-25%. The PPV, SVV, and SVI were measured using the Nexfin® device that employs noninvasive volume clamp plethysmography. RESULTS The area under the receiver operator characteristic curve gradually increased for PPV / SVV with higher threshold values (from 0.818 / 0.760 at 10% ↑SVI to 0.928 / 0.944 at 25% ↑SVI). The grey zone limits of both PPV and SVV changed from 9-16% (PPV) and 5-13% (SVV) at the 10% ↑SVI threshold to 18-21% (PPV) and 14-16% (SVV) at the 25% ↑SVI threshold. CONCLUSION Noninvasive PPV and SVV measurements allow an acceptable FR prediction, although the reliability of both variables is dependent on the intended increase in SVI, which improves substantially with concomitant smaller grey zones at higher ↑SVI thresholds.
منابع مشابه
Pulse Oximetry Wave Variation as a Noninvasive Tool to Assess Volume Status in Cardiac Surgery
OBJECTIVE To compare variations of plethysmographic wave amplitude (DeltaPpleth) and to determine the percent difference between inspiratory and expiratory pulse pressure (DeltaPp) cutoff values for volume responsiveness in a homogenous population of postoperative cardiac surgery patients. INTRODUCTION Intra-thoracic pressure variations interfere with stroke volume variation. Pulse pressure v...
متن کاملPassive leg raising predicts fluid responsiveness in the critically ill.
OBJECTIVE Passive leg raising (PLR) represents a "self-volume challenge" that could predict fluid response and might be useful when the respiratory variation of stroke volume cannot be used for that purpose. We hypothesized that the hemodynamic response to PLR predicts fluid responsiveness in mechanically ventilated patients. DESIGN Prospective study. SETTING Medical intensive care unit of ...
متن کاملStroke volume variation and pleth variability index to predict fluid responsiveness during resection of primary retroperitoneal tumors in Hans Chinese.
Respiration variation in arterial pulse pressure (ΔPP) and pulse oximetry plethysmographic waveform amplitude (ΔPOP) are accurate predictors of fluid responsiveness in mechanically ventilated patients. We hypothesized that stroke volume variation (SVV) and pleth variability index (PVI) can predict fluid responsiveness in mechanically ventilated patients during major surgical procedures in H...
متن کاملIs it safe to use supraglottic airway in children with difficult airways?
blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock. Chest 2001; 119: 867–73 16 Marik PE, Cavallazzi R, Vasu T, Hirani A. Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients. A systematic review of the literature. Crit Care Med 2009; 37: 2642–7 17 Benes J, Chytra I, Altmann P, et al. Intr...
متن کاملPredicting fluid responsiveness in children: a systematic review.
BACKGROUND Administration of fluid to improve cardiac output is the mainstay of hemodynamic resuscitation. Not all patients respond to fluid therapy, and excessive fluid administration is harmful. Predicting fluid responsiveness can be challenging, particularly in children. Numerous hemodynamic variables have been proposed as predictors of fluid responsiveness. Dynamic variables based on the he...
متن کامل