Detection of Measurement Outliers in Tracer Kinetics

نویسنده

  • Sung-Cheng Huang
چکیده

In tracer kinetic studies for extracting biological information, measurement noise and error in the kinetics could affect the reliability of the estimated biological parameters. While the effect of statistical noise has been studied extensively before, the effect of outliers has not been addressed as much. In this study, we described an algorithm for detecting and removing outliers. Computer simulation was used to generate kinetic data sets corresponding to those of the FDG tracer used in PET studies to evaluate the effect of outliers and the performance of the outlier detection algorithm. Results show that outlier could increase drastically the variability of the estimated rate constants of FDG transport and phosphorylation. The outlier detection algorithm imbedded in a regular model fitting procedure was found to have a low probability of missing outliers in the kinetics. The probability of falsely identifying non-outliers as outliers was high, but these false positive detections did not affect the reliability of the biological estimates. With the outlier detection, the variability of the parameter estimates in the simulated FDG kinetics with outliers could be reduced by a factor of more than 5. The present study demonstrated the importance of outlier detection in interpreting tracer kinetics. Some areas for future studies are also discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of Outliers and Influential Observations in Linear Ridge Measurement Error Models with Stochastic Linear Restrictions

The aim of this paper is to propose some diagnostic methods in linear ridge measurement error models with stochastic linear restrictions using the corrected likelihood. Based on the bias-corrected estimation of model parameters, diagnostic measures are developed to identify outlying and influential observations. In addition, we derive the corrected score test statistic for outliers detection ba...

متن کامل

Identification of outliers types in multivariate time series using genetic algorithm

Multivariate time series data, often, modeled using vector autoregressive moving average (VARMA) model. But presence of outliers can violates the stationary assumption and may lead to wrong modeling, biased estimation of parameters and inaccurate prediction. Thus, detection of these points and how to deal properly with them, especially in relation to modeling and parameter estimation of VARMA m...

متن کامل

Assessment of mediastinal tumors using SUVmax and volumetric parameters on FDG PET/CT

Objective(s): This study aimed to evaluate the role of pretreatment SUVmax and volumetric FDG positron emission tomography (PET) parameters in the differentiation between benign and malignant mediastinal tumors. In addition, we investigated whether pretreatment SUVmax and volumetric FDG-PET parameters could distinguish thymomas from thymic carcinomas, and low-risk from high-risk thymomas.Method...

متن کامل

Introduction Package CircOutlier For Detection of Outliers in Circular-Circular Regression

One of the most important problem in any statistical analysis is the existence of unexpected observations. Some observations are not a part of the study and are known as outliers. Studies have shown that the outliers affect to the performance of statistical standard methods in models and predictions. The point of this work is to provide a couple of statistical package in R software to identi...

متن کامل

The Effect of Different Stabilizers on Stability of Horseradish Peroxidase- Bovine Serum Albumin-Aflatoxin B1, a Conjugated Tracer for Detection of Aflatoxin B1 in Immunoassay-Based Methods

Aflatoxins are a group of fungal toxic metabolites, which are contaminated certain food commodities. ELISA is one of the sensitive methods for detection of aflatoxins. Preparation and stabilizing of a proper conjugated tracer for detection of aflatoxins is probably the main step for designing an ELISA method. In current study, different stabilizers were applied to stabilize a newly prepared con...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008