Monitoring of pre-frontal oxygen status in helicopter pilots using near-infrared spectrophotometers

نویسندگان

  • Azusa Kikukawa
  • Asao Kobayashi
  • Yoshinori Miyamoto
چکیده

BACKGROUND There are few in-flight studies of cognition-related cerebral oxygen status in helicopter pilots. METHODS Four male helicopter pilots volunteered for nine sorties during visual flight in a BK117 and UH-60J. The pilots' pre-frontal oxy-hemoglobin (O2Hb) and deoxy-hemoglobin (HHb) concentration were continuously monitored from the right/left sections of the forehead using near-infrared spectrophotometers with a consideration of motion artifacts. RESULTS The concentration of O2Hb progressively increased (13.98 micromol*L-1 as a maximum increased concentration) in both the right/left sections of the forehead from the basal level during the heightened cognitive demand of helicopter flight. There was comparatively little change (4.32 micromol*L-1 as a maximum increased concentration) in HHb concentration during measurement of helicopter flight. HHb changes were apparently not affected by a heightened cognitive demand of helicopter pilots. CONCLUSION These results demonstrate that near-infrared spectroscopy, especially O2Hb measurements, provides a sensitive method for the monitoring of cognitive demand (maneuvers) in helicopter pilots.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Frontal cortical oxygenation changes during gravity-induced loss of consciousness in humans: a near-infrared spatially resolved spectroscopic study.

Gravity (G)-induced loss of consciousness (G-LOC), which is presumably caused by a reduction of cerebral blood flow resulting in a decreased oxygen supply to the brain, is a major threat to pilots of high-performance fighter aircraft. The application of cerebral near-infrared spectroscopy (NIRS) to monitor gravity-induced cerebral oxygenation debt has generated concern over potential sources of...

متن کامل

Involuntary eye responses as measures of fatigue in US Army Apache aviators.

INTRODUCTION AH-64 Apache helicopter pilots fly the aircraft using a monocular helmet-mounted display that provides imagery from two separate forward-looking infrared sensors mounted on the nose of the aircraft. Studies have documented complaints of fatigue, headaches, and visual problems associated with the use of this sighting system. The goals of this study were: 1) to quantify possible flig...

متن کامل

Current and emerging technology in G-LOC detection: noninvasive monitoring of cerebral microcirculation using near infrared.

G-induced loss of consciousness (G-LOC) has emerged as an important operational problem of high-performance aircraft. Since it appears that G-LOC will continue to be a problem, a requirement exists to detect its occurrence in pilots so that the aircraft may be placed on autopilot. One excellent method of detecting G-LOC physiologically, one would assume, would be based on the oxidative status o...

متن کامل

4 Near - Infrared Spectroscopy

Near infrared spectroscopy (NIRS) is an imaging technique used in both clinical and emergency medicine, as well as in research laboratories to quantify and measure the oxygenation status of human tissue non-invasively. This is done by monitoring in vivo changes of the oxygen saturation of hemoglobin molecules in the body, based on the absorbance of near-infrared light by hemoglobin. With regard...

متن کامل

بررسی رفتار سری زمانی بازتاب طیفی و شاخص‌های پوشش گیاهی مزارع چغندرقند با استفاده از داده‌های سنجنده MODIS

Remote sensing technology is widely used in environmental and agricultural research, and nowadays it has become a valuable and reliable source of information for the management of crop production and assessment of global supply and demands for these products. The objective of this study was to investigate the feasibility of using MODIS data and vegetation indices based on sugar beet growth moni...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Dynamic Medicine : DM

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2008