Common Boiler Excess Air Trends and Strategies to Optimize Efficiency

نویسنده

  • Kevin Carpenter
چکیده

Boilers are among the most common heating equipment in commercial facilities, often consuming the majority of a facility’s fuel. The load on a boiler plant in a commercial facility constantly fluctuates depending on weather conditions, occupancy rate, and internal heat gains. Proper control of part-load operation can significantly affect energy use. Most boilers in medium-to-large commercial facilities are equipped with a single-point positioning control that has a shaft mechanically linking the fuel control valve with the combustion air damper. With this control, the air-to-fuel ratio is typically calibrated at high fire, or near 100% capacity. However, as the load on the boiler decreases and the fuel valve begins to close, the combustion air flow is decreased at a lower rate due to the non-linearity of the linkage between the fuel valve and the combustion air damper. This results in increased excess air levels at medium and low fire, yielding poorer efficiencies. While boilers could potentially have higher efficiencies at reduced firing rates, high excess air levels trump the efficiency gains at part-load and significantly lower the efficiency. Linkageless burner controls and O2 trim controls are much more energy-efficient combustion control packages. Both of these packages allow the fuel valve and combustion air damper to operate independently of one another. This paper presents case studies demonstrating trends in excess air over boilers’ firing range in commercial space-heating applications. Case studies include boilers with single-point positioning control and boilers with linkageless controls. For single-point positioning controls, the quantity of excess air rises with decreased firing rate, and the difference in excess air between high and low fire is typically between 40 and 80 percentage points. For linkageless controls, excess air remains relatively low throughout a burner’s firing rate.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Study on performance and methods to optimize thermal oil boiler efficiency in cement industry

Cement production is an energy-intensive process, so that the cement industry occupies a top position among other energy-consuming industries. Among the equipment used in cement industries, boilers are one of the energy-consuming equipment. Boilers are among the common heating equipment in industrial, commercial, and institutional facilities. In this paper, the performance of thermal oil bo...

متن کامل

Study on performance and methods to optimize thermal oil boiler efficiency in cement industry

Cement production is an energy-intensive process, so that the cement industry occupies a top position among other energy-consuming industries. Among the equipment used in cement industries, boilers are one of the energy-consuming equipment. Boilers are among the common heating equipment in industrial, commercial, and institutional facilities. In this paper, the performance of thermal oil bo...

متن کامل

Numerical simulation of Ramin's combustion chamber to investigate the factors affecting the production of carbon monoxide and nitrogen oxide

The boiler is one of the most vulnerable parts of a power plant, which is responsible for producing steam for moving turbines.  In order to increase the thermal efficiency of the power plant, it is necessary to prevent heat loss in the boiler combustion chamber and simultaneously control the environmental pollutant parameters such as NOx and CO.  Failure to control environmental pollutants will...

متن کامل

Measurements and Modeling of Flue Height Influence on Air Pollution Emissions and Thermal Efficiency of Natural Draught Gas Fired Boilers

This paper presents and analyses results from experimental and CFD work undertaken on a 24 kW domestic natural-draught gas fired boiler. The effect of chimney height on boiler flue gases is being considered to address the need for increasing concern over environmental safety as well as saving of energy. A multi-component analysis computer (DELTA 2000 CD) is used to analyze the flue gases. 3D nu...

متن کامل

Boiler Performance Optimization Using Fuzzy Logic Controller

This paper considers an approach to design a controller used for the air-to-fuel ratio (AFR) optimization in the combustion process of a power plant boiler. The optimization of the AFR will reduce the excess air level and improve the combustion efficiency in the boiler system. The combustion improvement indicates boiler operating cost savings. The fuzzy logic controller, which is a method of a ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008