A three-dimensional strain measurement method in elastic transparent materials using tomographic particle image velocimetry

نویسندگان

  • Azuma Takahashi
  • Sara Suzuki
  • Yusuke Aoyama
  • Mitsuo Umezu
  • Kiyotaka Iwasaki
چکیده

BACKGROUND The mechanical interaction between blood vessels and medical devices can induce strains in these vessels. Measuring and understanding these strains is necessary to identify the causes of vascular complications. This study develops a method to measure the three-dimensional (3D) distribution of strain using tomographic particle image velocimetry (Tomo-PIV) and compares the measurement accuracy with the gauge strain in tensile tests. METHODS AND FINDINGS The test system for measuring 3D strain distribution consists of two cameras, a laser, a universal testing machine, an acrylic chamber with a glycerol water solution for adjusting the refractive index with the silicone, and dumbbell-shaped specimens mixed with fluorescent tracer particles. 3D images of the particles were reconstructed from 2D images using a multiplicative algebraic reconstruction technique (MART) and motion tracking enhancement. Distributions of the 3D displacements were calculated using a digital volume correlation. To evaluate the accuracy of the measurement method in terms of particle density and interrogation voxel size, the gauge strain and one of the two cameras for Tomo-PIV were used as a video-extensometer in the tensile test. The results show that the optimal particle density and interrogation voxel size are 0.014 particles per pixel and 40 × 40 × 40 voxels with a 75% overlap. The maximum measurement error was maintained at less than 2.5% in the 4-mm-wide region of the specimen. CONCLUSIONS We successfully developed a method to experimentally measure 3D strain distribution in an elastic silicone material using Tomo-PIV and fluorescent particles. To the best of our knowledge, this is the first report that applies Tomo-PIV to investigate 3D strain measurements in elastic materials with large deformation and validates the measurement accuracy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of Unsteady Flow Fields for Flow Control Research by Means of Particle Image Velocimetry

Unsteady three-dimensional flow phenomena must be investigated and well understood to be able to design devices to control such complex flow phenomena in order to achieve the desired behavior of the flow and to assess their performance, even in harsh industrial environments. Experimental investigations for flow control research require measurement techniques capable to resolve the flow field wi...

متن کامل

Computed tomographic X-ray velocimetry for simultaneous 3D measurement of velocity and geometry in opaque vessels

Computed tomographic X-ray velocimetry has been developed for simultaneous three-dimensional measurement of flow and vessel geometry. The technique uses cross-correlation functions calculated from X-ray projection image pairs acquired at multiple viewing angles to tomographically reconstruct the flow through opaque objects with high resolution. The reconstruction is performed using an iterative...

متن کامل

Computed tomographic X-ray velocimetry for simultaneous measurement of 3D velocity and object geometry in opaque vessels

Computed tomographic X-ray velocimetry (CTXV) has been developed for simultaneous measurement of three-dimensional flow and vessel geometry. The technique uses cross-correlation functions calculated from X-ray projection image pairs acquired from multiple viewing angles to tomographically reconstruct the flow through opaque objects with high resolution The reconstruction is performed using an i...

متن کامل

A High Spatial Method to Determine Three-Dimensional Velocity Gradient Tensor using Micro Particle Image Velocimetry

Micro Particle Image Velocimetry (μPIV) is a non-invasive flow field measurement technique, which is becoming the method of choice for the investigation of micro-flows. Measurements of flows which occur within the human body represent one of the most important applications of μPIV. A three-component two-dimensional scanning micro-Particle Image Velocimetry (μPIV) technique is presented in this ...

متن کامل

Mandibular Dimensional Changes with aging in Three Dimensional Computed Tomographic Study in 21 to 50 Year old Men and Women

Introduction: Raising the knowledge of skeletal and soft tissue changes with aging has been highly essential due to an increasing demand for aesthetic facial surgery following aging. The aim of this study is to evaluate the three dimensional computed tomographic images and process of changes in mandible with aging. Materials and Methods: In this descriptive study, the facial CT scans were obta...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017