Anomolous IV behavior of ATLAS SCT microstrip sensors

نویسندگان

  • Y. Nakamura
  • K. Hara
  • K. Nakamura
  • K. Inoue
  • S. Shinma
  • Y. Ikegami
  • T. Kohriki
  • S. Terada
  • Y. Unno
چکیده

We observe deteriorated IV, leakage-to-voltage, characteristics when the ATLAS SemiConductor Tracker (SCT) silicon microstrip detector is biased at a fixed voltage Vk for a long period. The leakage current is nearly halved at voltages below Vk. The noise figure is deteriorated and signal charge spreads to neighboring strips. The detector performance is, however, not degraded when biased at or above Vk. We characterize the observed phenomena in detail in this article. r 2007 Elsevier B.V. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Characteristics of Irradiated Silicon Microstrip Detectors with h100i and h111i Substrates

In a program of developing radiation-hard silicon sensors for the LHC-ATLAS experiment, we have irradiated various types of silicon sensors with 12 GeV protons at KEK. Among the other properties, we made a comparative study of characteristics of the sensors with two wafer planes h1 1 1i and h1 0 0i. The studied sensors are p-on-n type, which satisfy the ATLAS-SCT specifications. Possible depend...

متن کامل

Detector modules for the ATLAS SCT endcaps

1976 double-sided detector modules are needed to equip the endcaps of the silicon microstrip tracker SCT of the ATLAS experiment at the LHC. This paper describes their design and presents results from a series of prototype

متن کامل

Construction of the ATLAS semi-conductor tracker (SCT) barrel modules in Japan

We have developed a semi-automated assembly system and constructed 124 silicon microstrip modules so far for the ATLAS SCT barrel. This article describes the assembly procedure, evaluations of precisions and the module survey results. A precision of B2 mm is achievable with this assembly system. r 2003 Elsevier B.V. All rights reserved.

متن کامل

Beamtest of Non-irradiated and Irradiated ATLAS SCT Microstrip Modules at KEK

-Non-irradiated and irradiated ATLAS SCT barrel and endcap modules have been beamtested with 4 GeV/c pions. Pulse shapes confirmed the peaking time of the amplifier to be 22 ns with slight deterioration in the irradiated modules. Median charges saturated around 3.8 fC both in the non-irradiated and irradiated modules. Signal/Noise ratios, using the noise estimates from the in-situ calibration, ...

متن کامل

Radiation Damage Studies of Silicon Microstrip Sensors

Various types of large area silicon microstrip detectors were fabricated for development of radiation-tolerant detectors operational in the LHC ATLAS SCT. The detectors were irradiated with 12-GeV protons at KEK to fluences of 1.7×10 and 4.2×10 protons/cm. Irradiated samples include n-on-n detectors with 4 kΩ cm bulk resistivity and p-on-n detectors with 1 kΩ cm and 4 kΩ cm bulk resistivities. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007