Airborne Particulate Matter and Bacteria Reduction from Spraying Slightly Acidic Electrolyzed Water in an Experimental Aviary Laying-Hen Housing System
نویسندگان
چکیده
Compared to conventional cage systems for laying hens, aviary housing systems generally have much higher concentrations of airborne dust and bacteria due to generation of bioaerosols by the hens from their litter access. Hence solutions to reduce these health-degrading agents are required to safeguard the indoor environment in such systems. Spraying slightly acidic electrolyzed water (SAEW) has been considered as a novel approach to reducing airborne bacteria and dust levels in hen houses. The objective of this study was to evaluate reduction of airborne bacteria and particulate matter (PM) by spraying SAEW (Trt) in an experimental aviary setting, as compared to no spraying (Ctrlns) or spraying tap water (Ctrlw). The hens were provided 16-hr light and 8-hr dark (16L:8D), with lights on at 6:00h and off at 22:00h, and were given access to the litter floor from 12:00h to 22:00h. The Trt regimen consisted of spraying SAEW at 14:00h for approximately 15 min at a dosage of 80 mL m-2; the Ctrlns regimen had no spraying; and the Ctrlw regimen consisted of spraying tap water following the same procedure as with Trt. Concentrations of airborne bacteria and PM were measured at 1.5 m above the floor in the center of the room. Airborne bacteria and PM concentrations in six size ranges (0.65-1.1, 1.1-2.1, 2.1-3.3, 3.3-4.7, 4.7-7.1, and > 7.1 Âμm) were measured at 13:45-14:00h and 14:45-15:00h for 15 min each. Compared to Ctrlns, spraying SAEW significantly reduced the airborne bacteria (> 2.1 Âμm) by up to 49±10% (P < 0.05), while Ctrlw did not show the reduction effect. No significant difference was found between Trt and Ctrlw in reducing airborne PM, although both reduced or tended to suppress PM >7.1 Âμm in size. The results show that spraying SAEW can effectively inactivate airborne bacteria attached to the PM, thus is a promising technique for minimizing the adverse impacts of bioaerosols in aviary laying-hen housing systems.
منابع مشابه
Concentrations and Size Distributions of Airborne Particulate Matter and Bacteria in an Experimental Aviary Laying-Hen Housing System
High levels of airborne particulate matter (PM) and bacteria may exist in animal housing, which can be detrimental to the health of animals and workers. The sizes of these bioaerosols determine their aerialtransport behaviors and depositions in the respiratory tracts of animals and humans. However, little is known regarding the size distribution of airborne PM and bacteria in livestock houses, ...
متن کاملFree chlorine loss during spraying of membraneless acidic electrolyzed water and its antimicrobial effect on airborne bacteria from poultry house.
INTRODUCTION Spray-application of membraneless acidic electrolyzed water (MLAEW) is a novel technique for disinfection in livestock houses. This study investigated the loss of free chlorine (FC - the major germicidal component in MLAEW) over distance during spraying, as affected by air temperature and initial FC concentration. The anti-microbial effect of MLAEW on airborne bacteria from an avia...
متن کاملAmmonia, Greenhouse Gas, and Particulate Matter Concentrations and Emissions of Aviary Layer Houses in the Midwestern USA
There has been an increased interest in alternative housing for laying hens in certain parts of the world, including the United States. Associated with the movement are many questions to be addressed concerning sustainability of such systems. This study continually quantifies concentrations and emissions of ammonia (NH3), carbon dioxide (CO2), methane (CH4), and particulate matters (PM10 and PM...
متن کاملEnvironmental assessment of three egg production systems–Part I: Monitoring system and indoor air quality
To comprehensively assess conventional vs. some alternative laying-hen housing systems under U.S. production conditions, a multi-institute and multi-disciplinary project, known as the Coalition for Sustainable Egg Supply (CSES) study, was carried out at a commercial egg production farm in the Midwestern United States over two single-cycle production flocks. The housing systems studied include a...
متن کاملLung toxicity in mice of airborne particulate matter from a modern layer hen facility containing Proposition 2-compliant animal caging.
Proposition 2, which requires that egg-laying hens be confined only in ways that allow these animals to lie down, stand up, fully extend their limbs and turn around freely, was passed by the voters of California in 2008. These new housing requirements were introduced in the USA and European Union without considering the potential impact of changes in layer hen housing on the health of poultry w...
متن کامل