Development of ionization chamber for in-line intensity monitoring of large profile parametric X- ray beam

نویسندگان

  • T Tanaka
  • T Kuwada
  • Y Takahashi
  • K Hayakawa
  • K Nogami
  • K Nakao
  • M Inagaki
چکیده

An in-line ionization chamber has been developed for the real-time measurement of the absolute intensity of the pulsed parametric X-ray (PXR) beam during irradiation experiments. The quasi-monochromatic PXR generating system was developed at the Laboratory for Electron Beam Research and Application (LEBRA) in Nihon University. In contrast to typical narrow X-ray beams in synchrotron radiation facilities, the PXR beam profile is as large as approximately 100 mm in diameter with rather uniform flux distribution at the X-ray output port in the experimental hall. The energy of the PXR beam ranges from 5 to 34 keV, which is specified by the PXR target crystal plane and its geometrical condition. The ionization chamber is of a plane parallel type employing 6-μm thick double-sided aluminum vapor-deposited polyester films for the plane electrodes through which the X-ray beam passes. The plane bias electrode has been placed at an equal distance of 25 mm from the two plane earth electrodes that act as the beam windows with an aperture diameter of 120 mm. Due to the pulsed property of the PXR beam and the geometrical configuration of the ionization chamber, the charge-sensitive preamplifier output pulse height represents an integral of the fast electron current, corresponding to a half of the total ionization charge produced by the beam. The intensity of the PXR beam has been measured for various X-ray energies by using nitrogen and argon, respectively, as the filling gas.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preliminary Characterization Tests of Detectors of on-Line Monitor Systems of the Italian National Center of Oncological Hadron-Therapy (CNAO)

Introduction Hadron-therapy is an effective technique used to treat tumors that are located between or nearby vital organs. The Italian National Center of Oncological Hadron-therapy (CNAO) has been realized as the first facility in Italy to treat very difficult tumors with protons and Carbon ions. The on-line monitor system for CNAO has been developed by the Department of Physics of the Univers...

متن کامل

Ionization Chamber Detector for X-ray with Beam Position Monitoring

Ionization Chambers have been commonly used at beamlines in many synchrotron radiation facilities. Typical ADC ion chambers are pictured in Figure 1. The chambers generate a current proportional to the incident X-ray beam intensity. The ionization chamber allows users to determine the change in beam position in a single axis by comparing two signals that are created as the beam passes through t...

متن کامل

Dosimetric Evaluation of Linac Photon Small Fields using MAGIC Polymer Gels

Introduction: In radiotherapy, methods of treatment planning are becoming increasingly more complicated. This requires verification of the doses delivered to increasingly smaller and more precise regions. Radiotherapy techniques are continuously employing smaller and smaller field sizes to deliver tighter radiation doses with higher therapeutic ratios, generating interest among researchers to p...

متن کامل

Interpretation of In-air Output Ratio of Wedged Fields in Different Measurement Conditions

Introduction: The head scatter factor (Sc) is one of the important parameters for monitor unit (MU) calculation. There are multiple factors that impact the Sc values, such as, head structures, back scattering in to dose monitoring chambers, wedges and so on. This study aimed to investigate the variations of SC with different build-up cap materials, wall thickness, Source to ...

متن کامل

Assessment of an Unshielded Electron Field Diode Dosimeter for Beam Scanning in Small- to Medium-Sized 6 MV Photon Fields

Introduction Radiotherapy planning systems require many percentage depth dose (PDD) and profile measurements and there are various dosimeters that can be used to obtain these scans. As dose perturbation is particularly troublesome in smaller photon fields, using a low-perturbation, unshielded electron field diode (EFD) in these fields is of interest. The aim of this work was to investigate the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012