Association between GFR estimated by multiple methods at dialysis commencement and patient survival.
نویسندگان
چکیده
BACKGROUND AND OBJECTIVES The Initiating Dialysis Early and Late study showed that planned early or late initiation of dialysis, based on the Cockcroft and Gault estimation of GFR, was associated with identical clinical outcomes. This study examined the association of all-cause mortality with estimated GFR at dialysis commencement, which was determined using multiple formulas. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS Initiating Dialysis Early and Late trial participants were stratified into tertiles according to the estimated GFR measured by Cockcroft and Gault, Modification of Diet in Renal Disease, or Chronic Kidney Disease-Epidemiology Collaboration formula at dialysis commencement. Patient survival was determined using multivariable Cox proportional hazards model regression. RESULTS Only Initiating Dialysis Early and Late trial participants who commenced on dialysis were included in this study (n=768). A total of 275 patients died during the study. After adjustment for age, sex, racial origin, body mass index, diabetes, and cardiovascular disease, no significant differences in survival were observed between estimated GFR tertiles determined by Cockcroft and Gault (lowest tertile adjusted hazard ratio, 1.11; 95% confidence interval, 0.82 to 1.49; middle tertile hazard ratio, 1.29; 95% confidence interval, 0.96 to 1.74; highest tertile reference), Modification of Diet in Renal Disease (lowest tertile hazard ratio, 0.88; 95% confidence interval, 0.63 to 1.24; middle tertile hazard ratio, 1.20; 95% confidence interval, 0.90 to 1.61; highest tertile reference), and Chronic Kidney Disease-Epidemiology Collaboration equations (lowest tertile hazard ratio, 0.93; 95% confidence interval, 0.67 to 1.27; middle tertile hazard ratio, 1.15; 95% confidence interval, 0.86 to 1.54; highest tertile reference). CONCLUSION Estimated GFR at dialysis commencement was not significantly associated with patient survival, regardless of the formula used. However, a clinically important association cannot be excluded, because observed confidence intervals were wide.
منابع مشابه
Beta trace protein as GFR marker in children
Background and Objective: Serum creatinine is the most used endogenous marker of glomerular filtration rate (GFR), but it also has multiple limitations. Therefore, some surrogate GFR markers, such as beta trace protein, have been introduced for GFR estimation. The aim of our study was to estimate GFR by serum beta trace protein using three available equations and compare them to DTPA GFR as the...
متن کاملChronic kidney disease and 1-year survival in elderly patients discharged from acute care hospitals: a comparison of three glomerular filtration rate equations.
BACKGROUND Glomerular filtration rate (GFR) is directly associated with survival. However, the prognostic significance of GFR might be different according to the formula used to estimate it. We aimed at comparing the association between GFR estimated using three different formulas and 1-year survival in elderly patients discharged from acute care hospitals. METHODS Our series consisted of 439...
متن کاملSAPS 3 at dialysis commencement is predictive of hospital mortality in patients supported by extracorporeal membrane oxygenation and acute dialysis.
OBJECTIVE This study examined the association between hospital mortality and five illness-severity scoring systems evaluated at different time points in the intensive care unit (ICU) as well as clinical variables as predictors in critically ill patients supported by extracorporeal membrane oxygenation (ECMO) and acute dialysis. METHODS This multicenter prospective observational study included...
متن کاملGFR measurement with iohexol and 51Cr-EDTA. A comparison of the two favoured GFR markers in Europe.
BACKGROUND The aim of the present study was to compare the most commonly used GFR markers for clearance measurements, 51Cr-EDTA and iohexol, using two different methods for iohexol analysis, HPLC and X-ray fluorescence, referring both to the multiple-sample and single-sample calculations, using 51Cr-EDTA as the reference method. METHODS Forty-nine patients with an estimated GFR >40 ml/min wer...
متن کاملN-Acetylcysteine does not artifactually lower plasma creatinine concentration.
BACKGROUND All randomized controlled trials of N-acetylcysteine (NAC) in contrast media-induced nephropathy used creatinine as a marker of renal function. However, it has been suggested that NAC may lower plasma creatinine levels independent of any effects on glomerular filtration rate (GFR). METHODS At a tertiary hospital 110 cardiac surgical patients were randomly allocated to peri-operativ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical journal of the American Society of Nephrology : CJASN
دوره 9 1 شماره
صفحات -
تاریخ انتشار 2014