Rf Tests of an 805 Mhz Pillbox Cavity at Lab G of Fermilab*

نویسندگان

  • Derun Li
  • J. Corlett
  • R. MacGill
  • J. Wallig
  • M. Zisman
چکیده

We report recent high power RF tests on an 805 MHz RF pillbox cavity with demountable windows for beam apertures at Lab G of Fermilab, a dedicated facility for testing of MUCOOL (muon cooling) components. The cavity is installed inside a superconducting solenoidal magnet. A 12 MW peak RF power klystron is used for the tests. The cavity has been processed both with and without magnetic field. Without magnetic field, a gradient of 34 MV/m was reached rather quickly with very low sparking rate. In a 2.5 T solenoidal field, a 16 MV/m gradient was achieved, and it had to take many weeks of conditioning. Strong multipacting effects associated with high radiation levels were measured during the processing with the magnetic field. More recently Be windows with TiN-coated surface have been installed and tested at conditions of with and without the external magnetic field. A conservative 16 MV/m gradient without magnetic field was reached quickly as planned. Less multipacting was observed during the conditioning, it indicated that the TiN-coated surface on the windows had indeed helped to reduce the secondary electron emissions significantly. A modest gradient of 16.5 MV/m was finally achieved with magnet on in solenoidal mode and the field up to 4 T. Preliminary inspection on Be windows surface found no damage at all, in comparison with Cu windows where substantial surface damage was found. Preliminary understanding of conditioning cavity in a strong magnetic field has been developed. More through window and cavity surface inspection is under way.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

81 52 18 A ug 2 00 0 RF CAVITIES FOR THE MUON AND NEUTRINO FACTORY COLLABORATION STUDY

A multi-laboratory collaboration is studying the feasibility of building a muon collider, the first phase of which maybe a neutrino factory. The phase space occupied by the muons is very large and needs to be cooled several orders of magnitude for either machine, 100,000 to 1 million for the collider and ten to 100 for the factory. Ionization cooling is the baseline method for muon cooling. Thi...

متن کامل

Rf Cavities for the Muon and Neutrino Factory

A multi-laboratory collaboration is studying the feasibility of building a muon collider, the first phase of which maybe a neutrino factory. The phase space occupied by the muons is very large and needs to be cooled several orders of magnitude for either machine, 100,000 to 1 million for the collider and ten to 100 for the factory. Ionization cooling is the baseline method for muon cooling. Thi...

متن کامل

A 201 Mhz Rf Cavity Design with Non-stressed Pre-curved Be Windows for Muon Cooling Channels*

We present a 201-MHz RF cavity design for muon cooling channels with non-stressed and pre-curved Be foils to terminate the beam apertures. The Be foils are necessary to improve the cavity shunt impedance with large beam apertures needed for accommodating large transverse size muon beams. Be is a low-Z material with good electrical and thermal properties. It presents an almost transparent window...

متن کامل

طراحی کاواک 100 مگاهرتز برای حلقه انبارش چشمه نور ایران

Iranian Light Source Facility (ILSF) RF system was conceptually designed based on ILSF requirements for a 3 GeV storage ring and 400 mA beam current at 500 MHz RF frequency. Considering the fact that  cavity construction is simpler at 100 MHz and advantages of reducing frequency provided an alternative of 100MHz RF system to be explored for ILSF. After a thorough study on the effect of reducing...

متن کامل

The Spallation Neutron Source (sns) Linac Rf System*

The SNS is a spallation neutron research facility being built at Oak Ridge National Laboratory in Tennessee [1]. The Linac portion of the SNS (with the exception of the superconducting cavities) is the responsibility of the Los Alamos National Laboratory (LANL), and this responsibility includes the RF system for the entire linac. The linac accelerates an average beam current of 2 mA to an energ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003