The effect of lumbar-pelvic alignment and abdominal muscle thickness on primary dysmenorrhea

نویسندگان

  • Moon-jeong Kim
  • Il-hun Baek
  • Bong-oh Goo
چکیده

[Purpose] The purpose of this study was to identify effects of malalignment of the lumbar pelvis, as a passive element, and the thicknesses of abdominal muscles, as active elements, on primary dysmenorrhea. [Subjects and Methods] The subjects were divided into a primary dysmenorrhea group and normal group according to Visual Analogue Scale, and ultimately there were 28 subjects in the dysmenorrhea group and 22 subjects in the normal group. Alignment of the lumbar pelvis was measured by using a Formetric 4D analysis system, and the thicknesses of abdominal muscles were measured by using ultrasound imaging. [Result] Scoliosis was 6.7 ± 4.3° in the primary dysmenorrhea group and 3.8 ± 2.0° in the normal group, and the lordotic angles of the two groups were 0.6 ± 0.5° and 0.1 ± 0.3°, respectively. The thickness of the internal oblique was 3.8 ± 1.3 mm in the primary dysmenorrhea group and 6.0 ± 1.9 mm in the thicknesses of the transverse abdominis in the two groups were 2.6 ± 6.8 mm and 3.5 ± 6.1 mm, respectively. Furthermore, the thickness of the normal group, and the external oblique was 4.0 ± 0.8 mm in the primary dysmenorrhea group and 5.4 ± 1.4 mm in the normal group. [Conclusion] This study showed significant differences between the primary dysmenorrhea group and the normal group in lumbar-pelvic alignment and thicknesses of abdominal muscles.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effect of Imagery and Corrective Exercises on Model of Activity of Selected Pelvic Muscles and the Lumbar Hyper Extension Syndrome

Introduction: Lumbar hyper extension syndrome is the second most common category of lumbar syndromes that reduces the height of the disc and narrows the intervertebral foramen in the lumbar vertebrae. The purpose of this study was the effect of exercises (imagery and corrective) on the degree of lumbar hyper extension and the activity of electromyography of the pelvic muscles. Methods: Twenty-...

متن کامل

Effect of Stabilization Exercise on Lumbar Multifidus Muscle Thickness in Patients with Non-specific Chronic Low Back Pain

Objectives: In a single blinded randomized controlled study, we investigated the effect of stabilization exercise on lumbar multifidus muscle thickness in patients with non-specific chronic low back pain. Low Back Pain is highly prevalent and results in considerable level of disability. Many causes have been associated with weakness or injury of the soft tissues in the lumbar area. Methods: ...

متن کامل

Electromyographic analysis of four techniques for isometric trunk muscle exercises.

Posture to avoid hyperextension of the lumbar spine during isometric trunk muscle exercises has been widely recommended. However, there are no common standards for cervical and pelvic alignment during exercises. To investigate the effects of four different techniques regarding cervical and pelvic alignment, electromyographic (EMG) and radiological studies were performed on 30 healthy subjects. ...

متن کامل

Reliability of Eelectromyography of Abdominal Muscles During Abdominal Manoeuvre with and without Pelvic Floor Muscle Contraction

Objective: The purpose of this study was to determine the reliability of electromyography measurements of abdominal muscles activity during different manoeuvres (pelvic floor muscle (PFM) contraction, abdominal hollowing and abdominal bracing with and without PFM contraction) in subjects with and without chronic low back pain (LBP). Materials & Methods: In this methodology research 21 subjec...

متن کامل

The Effects of Precise Contraction of the Pelvic Floor Muscle Using Visual Feedback on the Stabilization of the Lumbar Region

[Purpose] The purpose of this study is to verify whether precise contraction of the pelvic floor muscle (PFM) using visual feedback actually affects the thickness of abdominal muscles. [Subjects] The subjects were 29 healthy adults in their 20s who consented to participate in this study. [Methods] This study provided visual feedback on PFM using one ultrasound device and identified changes in t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 28  شماره 

صفحات  -

تاریخ انتشار 2016