Frequency of permanent pacemaker or implantable cardioverter-defibrillator infection in patients with gram-negative bacteremia.

نویسندگان

  • Daniel Z Uslan
  • Muhammad R Sohail
  • Paul A Friedman
  • David L Hayes
  • Walter R Wilson
  • James M Steckelberg
  • Larry M Baddour
چکیده

BACKGROUND Despite the frequent occurrence of bacteremia due to gram-negative organisms in patients with underlying permanent pacemakers (PPMs) or implantable cardioverter defibrillators (ICDs), the outcome and treatment of these patients has received scant attention. In patients with PPMs or ICDs who have Staphylococcus aureus bacteremia, 45% have PPM/ICD infection. METHODS We conducted a retrospective cohort study over a 7-year period to assess the clinical features and frequency of PPM/ICD infection in patients with gram-negative bacteremia, as well as the incidence of relapse in patients for whom the device was not removed. RESULTS Forty-nine patients were included in the study; 3 (6%) had either definite (2 patients) or possible (1 patient) PPM/ICD infection. Both patients with definite PPM/ICD infection had clear infection of the generator pocket. None of the other patients with alternate sources of bacteremia developed PPM/ICD infection. Thirty-four patients with retained PPM/ICD were observed for >12 weeks (median time, 759 days), and 2 (6%) developed relapsing bacteremia, although they each had alternative sources of relapse. CONCLUSIONS In sharp contrast to S. aureus infection, PPM/ICD infection in patients with gram-negative bacteremia was rare, and no patients appeared to have secondary PPM/ICD infection due to hematogenous seeding of the system. Despite infrequent system removal in these patients, relapsing bacteremia among patients who survived initial bacteremia was rarely seen. If secondary PPM/ICD infection occurs in patients with gram-negative bacteremia, it is either uncommon or it is cured with antimicrobial therapy despite device retention.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automatic implantable cardioverter defibrillator pocket infection due to Providencia rettgeri: a case report

Coagulase-negative staphylococci and Staphylococcus aureus are the commonest pathogens involved in infections of pacemaker-defibrillator systems. Among causative Gram-negative bacteria, infections due to Klebsiella, Serratia, Pseudomonas, Acinetobacter and other species have been reported. We report herein a unique case of an automatic implantable cardioverter defibrillator infection due to Pro...

متن کامل

THE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL

Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...

متن کامل

Staphylococcus aureus bacteremia in patients with permanent pacemakers or implantable cardioverter-defibrillators.

BACKGROUND Although cardiac device infections (CDIs) are a devastating complication of permanent pacemakers or implantable cardioverter-defibrillators, the incidence of CDI in patients with bacteremia is not well defined. The objective of this study was to determine the incidence of CDI among patients with permanent pacemakers or implantable cardioverter-defibrillators who develop Staphylococcu...

متن کامل

Is correction for metallic artefacts mandatory in cardiac SPECT/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?

Introduction: Metallic artifacts due to pacemaker/ implantable cardioverter defibrillator (ICD) leads in CT images can produce artifactual uptake in cardiac SPECT/CT images. The aim of this study was to determine the influence of the metallic artifacts due to pacemaker and ICD leads on myocardial SPECT/CT imaging. Methods: The study included 9 patients wh...

متن کامل

Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus

Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical infectious diseases : an official publication of the Infectious Diseases Society of America

دوره 43 6  شماره 

صفحات  -

تاریخ انتشار 2006