0 B Eam Current Monitors in the Nlcta

نویسندگان

  • Christopher Nantista
  • Chris Adolphsen
چکیده

The current profile along the 126 ns, multi-bunch beam pulse in the Next Linear Collider Test Accelerator (NLCTA) is monitored with fast toroids (rise time ~1 ns). Inserted at several positions along the beam line, they allow us to track current transmission as a function of position along the bunch train. Various measurements, such as rise time, current, width, and slope, are made on the digitized signals, which can be corrected in software by means of stored frequency response files. The design and implementation of these devices is described.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ar X iv : p hy si cs / 0 00 70 14 7 Ju l 2 00 0 BEAM PROFILE MONITORS IN THE NLCTA

The transverse current profile in the Next Linear Collider Test Accelerator (NLCTA) electron beam can be monitored at several locations along the beam line by means of profile monitors. These consist of insertable phosphor screens, light collection and transport systems, CID cameras, a frame-grabber, and PC and VAX based image analysis software. In addition to their usefulness in tuning and ste...

متن کامل

Beam Profile Monitors in the Nlcta *

The transverse current profile in the Next Linear Collider Test Accelerator (NLCTA) electron beam can be monitored at several locations along the beam line by means of profile monitors. These consist of insertable phosphor screens, light collection and transport systems, CID cameras, a frame-grabber, and PC and VAX based image analysis software. In addition to their usefulness in tuning and ste...

متن کامل

Beam Current Monitors in the Nlcta*

The current profile along the 126 ns, multi-bunch beam pulse in the Next Linear Collider Test Accelerator (NLCTA) is monitored with fast toroids (rise time -1 ns). Inserted at several positions along the beam line, they allow us to track current transmission as a function of position along the bunch train. Various measurements, such as rise time, current, width, and slope, are made on the digit...

متن کامل

A new modified animal model of myosin-induced experimental autoimmune myositis enhanced by defibrase

INTRODUCTION We investigated the effect of defibrase (a proteolytic enzyme extraction of Agkistrodon halys venom) on experimental autoimmune myositis (EAM) in guinea pigs and explored the option of using a modified pig model of EAM to enhance the study of this disease. MATERIAL AND METHODS Guinea pigs were divided into 3 groups: group A (control group) was immunized with complete Freund adjuv...

متن کامل

The next Linear Collider Test Accelerator+

During the past several years, there has been tremendous progress on the development of the RF system and accelerating structures for a Next Linear Collider (NLC). Developments include high-power klystrons, RF pulse compression systems and damped/detuned accelerator structures to reduce wakefields. In order to integrate these separate development efforts into an actual X-band accelerator capabl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000