A Biomechanical Comparison of Proportional Electromyography Control to Biological Torque Control Using a Powered Hip Exoskeleton

نویسندگان

  • Aaron J. Young
  • Hannah Gannon
  • Daniel P. Ferris
چکیده

BACKGROUND Despite a large increase in robotic exoskeleton research, there are few studies that have examined human performance with different control strategies on the same exoskeleton device. Direct comparison studies are needed to determine how users respond to different types of control. The purpose of this study was to compare user performance using a robotic hip exoskeleton with two different controllers: a controller that targeted a biological hip torque profile and a proportional myoelectric controller. METHODS We tested both control approaches on 10 able-bodied subjects using a pneumatically powered hip exoskeleton. The state machine controller targeted a biological hip torque profile. The myoelectric controller used electromyography (EMG) of lower limb muscles to produce a proportional control signal for the hip exoskeleton. Each subject performed two 30-min exoskeleton walking trials (1.0 m/s) using each controller and a 10-min trial with the exoskeleton unpowered. During each trial, we measured subjects' metabolic cost of walking, lower limb EMG profiles, and joint kinematics and kinetics (torques and powers) using a force treadmill and motion capture. RESULTS Compared to unassisted walking in the exoskeleton, myoelectric control significantly reduced metabolic cost by 13% (p = 0.005) and biological hip torque control reduced metabolic cost by 7% (p = 0.261). Subjects reduced muscle activity relative to the unpowered condition for a greater number of lower limb muscles using myoelectric control compared to the biological hip torque control. More subjects subjectively preferred the myoelectric controller to the biological hip torque control. CONCLUSION Myoelectric control had more advantages (metabolic cost and muscle activity reduction) compared to a controller that targeted a biological torque profile for walking with a robotic hip exoskeleton. However, these results were obtained with a single exoskeleton device with specific control configurations while level walking at a single speed. Further testing on different exoskeleton hardware and with more varied experimental protocols, such as testing over multiple types of terrain, is needed to fully elucidate the potential benefits of myoelectric control for exoskeleton technology.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Heuristic-based online adaptation of ankle exoskeleton assistance using plantarflexor electromyography

INTRODUCTION People often change their coordination strategies as they learn to walk with ankle exoskeletons [1], yet most current exoskeleton control approaches do not appropriately account for these changes. Timebased assistance techniques, in which the exoskeleton is actuated at a specific point in the gait cycle [2, 3], keep device behavior static regardless of human adaptation. Proportiona...

متن کامل

Gastrocnemius Myoelectric Control of a Robotic Hip Exoskeleton Can Reduce the User's Lower-Limb Muscle Activities at Push Off

We present a novel assistive control strategy for a robotic hip exoskeleton for assisting hip flexion/extension, based on a proportional Electromyography (EMG) strategy. The novelty of the proposed controller relies on the use of the Gastrocnemius Medialis (GM) EMG signal instead of a hip flexor muscle, to control the hip flexion torque. This strategy has two main advantages: first, avoiding th...

متن کامل

A Continous Rotary Actuation Mechanism for a Powered Hip Exoskeleton

Follow this and additional works at: http://scholarworks.umass.edu/masters_theses_2 Part of the Biomechanical Engineering Commons, Biomechanics and Biotransport Commons, Biomedical Devices and Instrumentation Commons, Computer-Aided Engineering and Design Commons, Controls and Control Theory Commons, Electro-Mechanical Systems Commons, Robotics Commons, and the Systems and Integrative Engineeri...

متن کامل

Embedded Control System for a Powered Leg Exoskeleton

Fig. 1. The exoskeleton for knee support. trol system for a powered orthosis is presented. The orthosis (as shown in Fig. 1) is used to support the thigh muscles during flexion and extension of the knee while performing common motions like getting up from a chair, walking, or climbing stairs. The user interface of the control system is implemented by evaluating EMG signals from significant thig...

متن کامل

Comparison of Torque Controllers for an Ankle Exoskeleton with a Series Elastic Actuator Driven by a Uni-directional Bowden Cable during Walking

Exoskeletons have been used for human performance restoration and enhancement for many years. Due to the dynamic nature of human locomotion, torque control is widely used in lower-limb exoskeleton assistance during stance phases of walking. In these systems, series-elastic actuators (SEA) are commonly used to provide low error torque tracking in the presence of unknown and changing human dynami...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2017