Ionization and double ionization of small water clusters.
نویسندگان
چکیده
The valence ionization and double ionization spectra of the water molecule, of the water dimer, and the cyclic water clusters (H2O)3 and (H2O)4 are calculated by ab initio Green's function methods and discussed in some detail. Particular attention is paid to the analysis of the development of the spectra with increasing cluster size. Electronic decay following inner valence ionization is addressed and a crude estimate for the kinetic energy spectrum of the secondary electrons is given for the clusters.
منابع مشابه
Double ionization energy spectra of small alkali- metal clusters
In this article, we calculate the spectra of the double ionization energy (the energy required for adding two electrons to the neutral system) of small alkali-metal clusters (K2 and Li2) including the effect of electron–electron short-range correlation by adding two one-particle energies within the GW approximation and taking into account the electron–electron repulsive interaction effectively....
متن کاملCalculation of the triple and double cross sections in the proton-hydrogen impact at the ionization channel by removing singularity in the scattering amplitudes
In the present work, the triple and double cross sections of atomic hydrogen ionization in collision with the proton are calculated. The potential of the interaction is considered as a Coulombic; also, the first and second order Born approximations have been used. The singularity of the Green operator in the second order approximation has been removed for the analytical solution of the scatt...
متن کاملDetermination of 2-phenylethanol in Rose Water Using Dispersive Liquid-Liquid Microextraction with Gas Chromatography Flame Ionization Detection
A simple and rapid microextraction procedure based on dispersive liquid-liquid microextraction (DLLME) coupled with gas chromatography-flame ionization detection (GC-FID) was developed for the extraction and analysis of 2-phenylethanol in rose water sample. In the proposed approach, carbon tetrachloride and ethanol were used as extraction and dispersive solvents, respectively. Some important pa...
متن کاملCalculations of absorbed dose and energy dependent of small-scale dosimeters for photons beam therapy
In this study, the energy dependency for dosimeters of air ionization chambers, lithium fluoride, silicon and plastic scintillator has been studied using the MCNPX Monte Carlo simulation code and simulated for gamma energy in the range of radiotherapy energy. The simulation results show that the response of each of the dosimeters for gamma photon beams in the energy range of 0.2 to 20 MeV varie...
متن کاملStandard calibration of ionization chambers used in radiation therapy dosimetry and evaluation of uncertainties
Background: Absolute dosimetry of external beam radiotherapy is carried out by the use of ionization chambers. These chambers must be calibrated at a standard dosimetry laboratory before any use in clinical dosimetry. The secondary standard dosimetry laboratory of Iran (SSDL) has the duty of calibrating the ionization chambers used in radiotherapy centers in Iran. Materials and Methods...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of chemical physics
دوره 125 20 شماره
صفحات -
تاریخ انتشار 2006