Volar Locking Plate Breakage after Nonunion of a Distal Radius Osteotomy
نویسندگان
چکیده
We report a 38-year-old male with a nonunion followed by plate breakage after volar plating of a distal radius osteotomy. Volar locking plates have added a new approach to the treatment of distal radius malunions, due to a lower morbidity of the surgical approach and the strength of the final construction, allowing early mobilization and return to function. Conclusion. Plate breakage is an uncommon complication of volar locking plate fixation. To our knowledge, few cases have been described after a distal radius fracture and no case has been described after a distal radius corrective osteotomy. In the present case, plate breakage appears to have occurred as a result of a combination of multiple factors as the large corrective lengthening osteotomy, the use of demineralized bone matrix instead of bone graft, and the inappropriate fixation technique as an unfilled screw on the osteotomy site, rather than the choice of plate.
منابع مشابه
Distal radius nonunion after volar locking plate fixation of a distal radius fracture: a case report
We describe a 59-year-old man who had nonunion of a right distal radius fracture after volar locking plate fixation. He underwent open reduction and internal fixation with a volar locking plate system for a dorsally displaced, unstable distal radius fracture at a previous hospital 5 months ago. Radiographs of the injured wrist showed nonunion of the distal radius with 1.5-mm ulnar minus varianc...
متن کاملFailure of volar locking plate fixation of an extraarticular distal radius fracture: A case report
BACKGROUND Volar locking plates provide significant structural stability to the distal radius. Failure of a volar locked plating is a rarely reported complication in the literature. CASE PRESENTATION A 40 year-old, obese female patient who presented with a displaced extraarticular distal radius fracture, underwent open reduction and internal fixation of the fracture using a volar locking plat...
متن کاملBreakage of a volar locking plate after delayed union of a distal radius fracture.
This is a case report of a 58-year-old obese, diabetic female who sustained a dorsally angulated distal radius fracture, treated with a volar locking plate. Union was delayed and the plate broke. The fracture healed after repeated surgery involving replacement of the plate and grafting with demineralised bone matrix. Delayed unions of distal radius fractures are rare. This case shows that fract...
متن کاملMechanical failure of the distal radius volar locking plate.
PURPOSE To review 9 cases of mechanical failure of the volar locking plate for distal radial fractures. METHODS Records of 374 consecutive patients who underwent volar locking plating for distal radial fractures were reviewed. Mechanical failures of the volar locking plate were defined as plate breakage or bending, screw breakage or loosening, or collapse of articular fragments resulting in i...
متن کاملComparison of a new intramedullary scaffold to volar plating for treatment of distal radius fractures.
OBJECTIVES To compare the biomechanical properties of a new nitinol intramedullary (IM) scaffold implant with those of volar plates for the treatment of dorsally comminuted extra-articular distal radius fractures using an established model. METHODS A dorsal wedge osteotomy was performed on a bone model to simulate a dorsally comminuted extra-articular distal radius fracture. This model was us...