Dose equivalent from 500 MeV neutrons

نویسندگان

  • S. Beceiro
  • G. Fehrenbacher
  • F. Gutermuth
  • E. Kozlova
  • T. Radon
چکیده

Neutrons constitute a major component in the radiation fi eld outside the shielding of particle accelerators. Consequently appropriate neutron dose meters are needed to survey the radiation levels. A thermo-luminescence based neutron dosemeter is used at the UNILAC as well as at the SIS. It has been modifi ed to improve the response for high energetic neutrons (extended range). We report on a test of these devices in a quasi mono-energetic fi eld of 500 MeV neutrons.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Study of the absorbed dose rate of all rays emitted from the 252Cf brachytherapy source by the Monte Carlo method

The 252Cf brachytherapy source is a spontaneous fission decay source, which is used as a neutron-emitting source. In addition to neutrons emitted from this source, gamma rays are also emitted with the average energy of 1 MeV. In this study, using the Monte Carlo N-Particle code (MCNPX), the absorbed dose rates of the neutrons, the primary gamma and the secondary gamma that generated by thermal ...

متن کامل

Evaluation of the dose and flux of secondary particles in the lung tissue in breast proton therapy using the Monte Carlo simulation code

Unlike proton therapy, conventional radiation therapy directs X-rays not only at the tumor but also unavoidably at nearby healthy tissue. Protons deliver radiation to tumor tissue while the healthy structures will be spared during proton therapy. When protons travel through matter, secondary particles like neutrons and photons are produced. It is believed that the secondary dose can lead to sec...

متن کامل

Calculation of the Equivalent Dose of the First and the Most Important Secondary Particles in Brain Proton Therapy by Monte Carlo Simulation

Introduction: Due to nuclear interactions between the tissues and high-energy protons, the particles, including neutrons, positrons, and photons arise during proton therapy. This study aimed at investigating the dose distribution of proton and secondary particles, such as positrons, neutrons, and photons using the Monte Carlo method. Material and Methods:<...

متن کامل

Assessment of secondary particles in breast proton therapy by Monte Carlo simulation code using MCNPX

Background: The present study aimed to investigate the equivalent dose in vital organs, including heart and lung, due to secondary particles produced during breast proton therapy. Materials and Methods: The numerical ORNL female-phantom was improved and simulated using the Monte Carlo MCNPX code. The depth-dose profile of proton beams with different energies was simulated. The proper energy ran...

متن کامل

Investigation of Medical Neutron Radiation Doses Using Two types of bubble Detectors

This study measured the amount of pollution of fast and slow neutrons generated from a Elekta Synergy linear accelerator, using various photons and electrons and two bubble detectors, BDT and BD-PND. The BDT bubble detector is preferentially sensitive to thermal neutrons. The BDPND is the recommended detector for personal neutron dosimetry.First, 10-MV photon radiation fields of 40×40 cm, 30×30...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006