A comparison of responses to albuterol delivered by two aerosol devices.

نویسندگان

  • R Olivenstein
  • N Wolkove
  • C Cohen
  • H Frank
  • H Kreisman
چکیده

Nineteen outpatients with stable obstructive pulmonary disease (mean forced expiratory volume in one second [FEV1], 1.00 + 0.10 L) were evaluated for airway response to albuterol (salbutamol) administered by metered-dose inhaler and Bosch ultrasonic nebulizer (BUSN). Albuterol administered by metered-dose inhaler but not by nebulizer caused a significant increase in FEV1 and the mean forced expiratory flow over the middle half of the forced vital capacity (FEF25-75%) (p less than 0.02). Absolute increase from baseline of FEV1 and FEF25-75% was significantly greater for metered-dose inhaler (0.21 +/- 0.05 L; 0.32 +/- 0.13 L/sec) compared to ultrasonic nebulizer (0.07 +/- 0.03 L; 0.03 +/- 0.04 L/sec) (p less than 0.02). In 11 subjects (mean FEV1, 1.08 + 0.14 L), the placebo effect of inhalation of the diluent from the metered-dose inhaler (Freon) and the ultrasonic nebulizer (isotonic saline solution) was determined. Freon produced the mean increase of 1.5 percent, whereas the ultrasonic aerosol of isotonic saline solution resulted in a mean decrease of 8 percent in FEV1. Therefore, the inferior response to albuterol administered by ultrasonic nebulizer was at least in part due to the superimposed broncho-constriction occurring with ultrasonically administered saline solution. The metered-dose inhaler was more effective than the ultrasonic nebulizer for administration of albuterol in stable obstructive pulmonary disease, and the latter device is not recommended. A specific ultrasonic nebulizer should be prescribed only if its superiority to a metered-dose inhaler can be objectively documented.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative efficacy of inhaled albuterol between two hand-held delivery devices in horses with recurrent airway obstruction.

REASONS FOR PERFORMING STUDY Studies investigating the clinical efficacy of albuterol administered with the same propellant and commercially available delivery devices in horses with recurrent airway obstruction (RAO) are not currently available. OBJECTIVES To determine the efficacy of aerosolised albuterol administered to horses with RAO by means of 2 commercially available, hand-held delive...

متن کامل

Physicochemical aspects and efficiency of albuterol nebulization: comparison of three aerosol types in an in vitro pediatric model.

BACKGROUND Advances in nebulizer design have produced both ultrasonic nebulizers and devices based on a vibrating mesh (vibrating mesh nebulizers), which are expected to enhance the efficiency of aerosol drug therapy. The aim of this study was to compare 4 different nebulizers, of 3 different types, in an in vitro model using albuterol delivery and physical characteristics as benchmarks. METH...

متن کامل

Comparison of Aerosol Delivery by Face Mask and Tracheostomy Collar.

BACKGROUND The purpose of this study was to compare the performance of a tracheostomy collar, Wright mask, and aerosol mask attached to a jet nebulizer in facilitating aerosolized medication delivery to the lungs. We also compared albuterol delivery with open versus closed fenestration and determined the effect of inspiratory-expiratory ratio (I:E) on aerosol delivery. METHODS Albuterol (2.5 ...

متن کامل

Pressurized Metered-Dose Inhalers Versus Nebulizers in the Treatment of Mechanically Ventilated Subjects With Artificial Airways: An In Vitro Study.

BACKGROUND The primary focus of previous aerosol research during mechanical ventilation was the endotracheal tube (ETT). Consequently, there are limited data in the literature on the delivery of inhaled medications administered with different aerosol devices in mechanically ventilated patients with a tracheostomy tube (TT). The purpose of this study was to quantify and compare the efficiency of...

متن کامل

Comparison of HFNC, bubble CPAP and SiPAP on aerosol delivery in neonates: An in-vitro study.

UNLABELLED Aerosol drug delivery via high flow nasal cannula (HFNC), bubble continuous positive airway pressure (CPAP), and synchronized inspiratory positive airway pressure (SiPAP) has not been quantified in spontaneously breathing premature infants. OBJECTIVES The purpose of this study was to compare aerosol delivery via HFNC, bubble CPAP, and SiPAP in a model of a simulated spontaneously b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 90 3  شماره 

صفحات  -

تاریخ انتشار 1986