Performance of a fire detector based on a compact laser spectroscopic carbon monoxide sensor.
نویسندگان
چکیده
In this paper we show the suitability of a miniaturized tunable diode laser spectroscopy (TDLS)-based carbon-monoxide (CO) sensor for fire detection applications. The sensor utilizes a vertical-cavity surface-emitting laser (VCSEL) and inherent calibration scheme with reference gas filled in the photodetector housing. The fire-detection experiments are carried out under realistic conditions as described in the European standard EN54. The CO generation of all class C fires (according to EN54) could be well resolved. The cross-sensitivity to other substances was found to be very low: the maximum CO false response from cigarette smoke, hairspray and general aerosols reaches a low value of a few μL/L and only if the substance is directly applied into the sensor gas inlet. Therefore this sensor overcomes the disadvantage of high false alarm rate given by smoke detectors and is also in small size which is suitable for household and industrial applications. Hence, the VCSEL-based TDLS sensor is shown to have sufficient performance for fire-detection. It has advantages such as capability for fail-safe operation and, low cross-sensitivities as compared to existing point fire detector technology which is presently limited by these factors.
منابع مشابه
Novel diode laser-based sensors for gas sensing applications.
The development of compact spectroscopic gas sensors and their applications to environmental sensing will be described. These sensors employ mid-infrared difference-frequency generation (DFG) in periodically poled lithium niobate (PPLN) crystals pumped by two single-frequency solid state lasers such as diode lasers, diode-pumped solid state, and fiber lasers. Ultrasensitive, highly selective, a...
متن کاملField detection of CO and CH4 by NIR 2f modulation laser spectroscopy
A novel compact fiber-coupled NIR system based on a DFB diode laser source is employed as a portable and sensitive gas sensor for trace detection of combustion pollutant molecules. We demonstrate the performance of such an NIR gas sensor by tracing the absorption lines of CO and CH4 using 2f-WMS technique at moderate temperature of T ~ 600°C in the recuperator channel of an industrial furnace...
متن کاملEnd-tidal Carbon Dioxide Measurements in Unintentional Non-Fire-Related Carbon Monoxide Poisoning
Background: Poisoning with carbon monoxide occurs occasionally worldwide, and the gold diagnostic standard is to measure carboxyhemoglobin level in the blood. This study investigated the correlation between carboxyhemoglobin and the end-tidal carbon dioxide levels in 50 patients with carbon monoxide poisoning. Methods: We recruited 50 volunteer patients who had been admitted to the Emergency S...
متن کاملSMART ROOM CARBON MONOXIDE MONITORING AND CONTROL SYSTEM
Carbon Monoxide (CO) is the most abundant air pollutant gas and accumulates rapidly to dangerous concentrations even in areas that seem to be well ventilated. Carbon monoxide detectors/alarm systems exist but people who are old, hearing impaired, partially sighted or heavy sleepers may not get the warning or find it difficult to wake up and get out in the event of dangerous concentration of CO ...
متن کاملAdsorption of Carbon Monoxide on a (6, 6) Armchair Carbon Nanotube: Ab initio Study
Perhaps the more interesting nanostructures with large application potential, from transistors to probes, are carbon nanotubes. One of the most widely uses of these nanostructures are their applications as gas detector, which is an important application in the field se of environmental technologies. The present work studies the adsorption of carbon monoxide on a (6, 6) armchair carbon nanotube ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Optics express
دوره 22 11 شماره
صفحات -
تاریخ انتشار 2014