Intramedullary leg lengthening with a motorized nail

نویسندگان

  • Andreas H Krieg
  • Ulrich Lenze
  • Bernhard M Speth
  • Carol C Hasler
چکیده

BACKGROUND AND PURPOSE In the last decade, intramedullary limb lengthening has become a viable alternative to traditional external systems. We retrospectively analyzed the use of an intramedullary motorized nail (Fitbone) in a consecutive series of 32 patients. PATIENTS AND METHODS During the period September 2006 to December 2008, 32 consecutive patients with a median age of 17 (IQR: 15-19) years were treated with a fully implantable, motorized intramedullary lengthening device (Fitbone). The median leg length discrepancy was 35 (IQR: 30-44) mm at the femur (n = 21) and 28 (IQR: 25-30) mm at the tibia (n = 11). RESULTS Leg lengthening was successful in 30 of 32 cases, with no residual relevant discrepancy (± 5 mm). No intraoperative complications were observed. The consolidation index was significantly different (p = 0.04) between femoral lengthening (mean 35 days/cm) and tibial lengthening (mean 48 days/cm) but did not depend on age older/younger than 16 or previous operations at the affected site. 3 problems, 3 obstacles, and 4 complications (3 minor, 1 major) were encountered in 8 patients, 5 of which were implant-associated. INTERPRETATION This technique even allows correction in patients with multiplanar deformities. Compared to external devices, intramedullary systems provide comfort and reduce complication rates, give improved cosmetic results, and lead to fast rehabilitation since percutaneous, transmuscular fixation is prevented. This results in reasonable overall treatment costs despite the relatively high costs of implants.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Femoral lengthening with a motorized intramedullary nail

PURPOSE We assessed whether an intramedullary lengthening device would reduce the problems normally associated with the external fixation technique. We also wanted to determine whether it is a reliable construct for limb lengthening and deformity correction in the femur. PATIENTS AND METHODS We conducted a matched-pair comparison of 30 femoral lengthenings, 15 with a motorized intramedullary ...

متن کامل

Humerus Lengthening With the PRECICE Internal Lengthening Nail.

BACKGROUND Deformity and growth arrest of the humerus in children may result as sequelae of proximal humerus fractures and unicameral bone cysts, or as complications of their treatment. As approximately 80% of the growth of the humerus arises from the proximal physis, the resultant upper limb-length discrepancy can be substantial. Benefits to lengthening the shortened arm have been previously d...

متن کامل

Lengthening of the femur over an existing intramedullary nail.

Leg length discrepancies can occur despite successful union of femur fractures after intramedullary nailing (IMN). Often, the leg length discrepancy can result in significant disability to the patient, altered gait biomechanics, pelvic obliquity, and pain. Therefore, a successful clinical result for such deformities after IMN involves addressing the leg length inequality. Femoral reconstruction...

متن کامل

TECHNICAL TRICK Lengthening of the Femur Over an Existing Intramedullary Nail

Leg length discrepancies can occur despite successful union of femur fractures after intramedullary nailing (IMN). Often, the leg length discrepancy can result in significant disability to the patient, altered gait biomechanics, pelvic obliquity, and pain. Therefore, a successful clinical result for such deformities after IMN involves addressing the leg length inequality. Femoral reconstruction...

متن کامل

How precise is the PRECICE compared to the ISKD in intramedullary limb lengthening?

BACKGROUND AND PURPOSE The PRECICE intramedullary limb lengthening system uses a new technique with a magnetic rod and a motorized external remote controller (ERC) with rotational magnetic field. We evaluated the reliability and safety of the PRECICE system. METHODS We compared our preliminary results with PRECICE in 24 patients (26 nails) with the known difficulties in the use of mechanical ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 82  شماره 

صفحات  -

تاریخ انتشار 2011