Three-dimensional dynamic in vivo motion of the cervical spine: assessment of measurement accuracy and preliminary findings.

نویسندگان

  • Colin P McDonald
  • Casey C Bachison
  • Victor Chang
  • Stephen W Bartol
  • Michael J Bey
چکیده

BACKGROUND CONTEXT Previous research has quantified cervical spine motion with conventional measurement techniques (eg, cadaveric studies, motion capture systems, and fluoroscopy), but these techniques were not designed to accurately measure three-dimensional (3D) dynamic cervical spine motion under in vivo conditions. PURPOSE The purposes of this study were to characterize the accuracy of model-based tracking for measuring 3D dynamic cervical spine kinematics and to demonstrate its in vivo application. STUDY DESIGN Through accuracy assessment and application of technique, in vivo cervical spine motion was measured. METHODS The accuracy of model-based tracking for measuring cervical spine motion was determined in an in vitro experiment. Tantalum beads were implanted into the vertebrae of an ovine specimen, and biplane X-ray images were acquired as the specimen's neck was manually moved through neck extension and axial neck rotation. The 3D position and orientation of each cervical vertebra were determined from the biplane X-ray images using model-based tracking. For comparison, the position and orientation of each vertebra were also determined by tracking the position of the implanted beads with dynamic radiostereometric analysis. To demonstrate in vivo application of this technique, biplane X-ray images were acquired as a human subject performed two motion tasks: neck extension and axial neck rotation. The positions and orientations of each cervical vertebra were determined with model-based tracking. Cervical spine motion was reported with standard kinematic descriptions of translation and rotation. RESULTS The in vitro validation demonstrated that model-based tracking is accurate to within +/-0.6 mm and +/-0.6 degrees for measuring cervical spine motion. For the in vivo application, there were significant rotations about all three anatomical axes for both the neck extension and axial neck rotation motion tasks. CONCLUSIONS Model-based tracking is an accurate technique for measuring in vivo, 3D, dynamic cervical spine motion. Preliminary data acquired using this technique are in agreement with previous studies. It is anticipated that this experimental approach will enhance our understanding of cervical spine motion under normal and pathologic conditions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Three-dimensional assessment of the intervertebral kinematics after Mobi-C total disc replacement at the cervical spine in vivo using the EOS stereoradiography system

BACKGROUND Because 3-dimensional computed tomography and magnetic resonance imaging analysis of the spinal architecture is done with the patient in the supine position, stereoradiography may be more clinically relevant for the measurement of the relative displacements of the cervical vertebrae in vivo in the upright position. The innovative EOS stereoradiography system was used for measuring th...

متن کامل

Validation of Goniometric Method in the Assessment of Lordosis by Radiographic Analysis

Background & Aims: Cervical spine is prone to various abnormalities and sport injuries. There is still no non-aggressive measurement instrument with high reliability for easy and rapid assessment of cervical spine secondary complications. The aim of this research was to investigate the validity of goniometric method for cervical lordosis measurement through radiography. Method: In this study, 1...

متن کامل

Entrance skin dose assessment of selected computed radiography facilities in Ghana

Background: The basic challenge with computed radiography (CR) systems is the large dynamic range which provides an opportunity for radiographers to gradually increase exposure factors and still produce good image quality, a practice that can lead to dose creep. Materials and Methods: The aim of this study was to establish  the entrance skin dose (ESD) values for nine selected examinations in t...

متن کامل

بررسی تغییرات الگوی کنترل حرکت ستون فقرات کمری به‌دنبال افزایش مقاومت: مطالعه کلینیکی

Background: Joint trauma and injury are the most common causes of dynamic instability. Dynamic instability has a great effect on the lumbar spine, due to its three-dimensional motions. The greatest amounts of compression and shearing force are imposed at the points of maximum torque and velocity. The changes in these phase angles upon bearing various loads can cause some pathologic conditions. ...

متن کامل

Three-dimensional analysis of cervical spine segmental motion in rotation

INTRODUCTION The movements of the cervical spine during head rotation are too complicated to measure using conventional radiography or computed tomography (CT) techniques. In this study, we measure three-dimensional segmental motion of cervical spine rotation in vivo using a non-invasive measurement technique. MATERIAL AND METHODS Sixteen healthy volunteers underwent three-dimensional CT of t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The spine journal : official journal of the North American Spine Society

دوره 10 6  شماره 

صفحات  -

تاریخ انتشار 2010