Coherent ensemble averaging techniques for impedance cardiography

نویسندگان

  • Barry E. Hurwitz
  • Liang-Yu Shyu
  • Sridhar P. Reddy
  • Neil Schneiderman
  • Joachim H. Nagel
چکیده

EKG synchronized ensemble averaging of the impedance cardiogram tends to blur or suppress signal events due to signal jitter or event latency variability. Although ensemble averaging provides some improvement in the stability of the signal and signal to noise ratio under conditions of nonperiodic influences of respiration and motion, coherent averaging techniques were developed to determine whether further enhancement of the impedance cardiogram could be obtained. Physiological signals were obtained from sixteen male and female subjects during resting conditions. while delivering a speech and while undergoing submaximal bicycle exercise. Results indicated that improved resolution of dZ'dt signal events could be obtained using coherent ensemble averaging. Although some improvement in precision of event location was obtained, most enhancement of the impedance cardiogram occurred in measurement of the amplitude of the dZldt maximum (ejection velocity) during speaking and exercise conditions. Validated increases in dZldt maximum exceeding 20% were obtained in some subjects with coherent averaging. suggesting that the diagnostic utility of impedance cardiography can be improved by using this technique. (Supported by NHLBI research grants. HlA 1335 and HL36588.)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Large-scale ensemble averaging of ambulatory impedance cardiograms.

Impedance cardiography has been used increasingly to measure human physiological responses to emotional and mentally engaging stimuli. The validity of large-scale ensemble averaging of ambulatory impedance cardiograms was evaluated for preejection period (PEP), interbeat interval, and dZ/dt(min) amplitude. We tested whether the average of "classical" 60-sec ensemble averages across periods with...

متن کامل

Improved Detection of Ventricular Ejection Time for Impedance Cardiography

Impedance cardiography is a noninvasive technique for monitoring stroke volume (SV), based on sensing variation in the thoracic impedance due to blood flow. In this technique, first derivative of impedance (dz/dt) is used to calculate two parameters: ventricular ejection time and (-dz/dt)max. Respiration and motion artifacts cause base line drift in the sensed impedance waveform, and this resul...

متن کامل

استفاده از POD در استخراج ساختارهای متجانس‌ یک میدان آشفته آماری- همگن

Capability of the Proper Orthogonal Decomposition (POD) method in extraction of the coherent structures from a spatio-temporal chaotic field is assessed in this paper. As the chaotic field, an ensemble of 40 snapshots, obtained from Direct Numerical Simulation (DNS) of the Kuramoto-Sivashinsky (KS) equation, has been used. Contrary to the usual methods, where the ergodicity of the field is need...

متن کامل

Wavelet Based Denoising for Suppression of Motion Artifacts in Impedance Cardiography

Introduction Impedance cardiography is a noninvasive technique for monitoring the changes in the electrical impedance of the thorax z(t), caused by variation in the blood volume during the cardiac cycle [1]. Time derivative of the thoracic impedance is known as the impedance cardiogram (ICG) and it is used for estimating the ventricular ejection time (Tlvet), the negative peak of ICG ((-dz/dt)m...

متن کامل

Simultaneous acquisition of functional magnetic resonance images and impedance cardiography.

While simultaneous acquisition of electrocardiography (ECG) data during MRI is a widely used clinical technique, the effects of the MRI environment on impedance cardiography (ICG) data have not been characterized. We collected echo planar MRI scans while simultaneously recording ECG and thoracic impedance using carbon fiber electrodes and customized amplifiers. Here, we show that the key change...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1990