Transcatheter implantation of self-expandable valved prosthesis in outlet right ventricle an experimental study in pigs.
نویسندگان
چکیده
INTRODUCTION Patients with congenital heart disease who underwent pulmonary valvotomy or surgery to open the pulmonary valve ring are prone to develop residual pulmonary insufficiency or stenosis that may lead to right heart failure with clinical deterioration. These children require multiple interventions throughout their lives, which impose a high rate of morbidity and mortality. OBJECTIVE To develop a less invasive technique for implantation of a valved prosthesis through the right ventricle. METHODS The valved prosthesis consists of an auto expanding metal stent built with nitinol, surrounded with polyester, where the three leaflets of bovine pericardium were mounted. Twelve pigs were used to perform the implants. Echocardiographic control was performed immediately after implantation and one, four, eight and 12 weeks. RESULTS One animal showed reflux of moderate to severe and three mild reflux. Transvalvular gradients measured before implantation ranged from 3 to 6 mmHg and that soon after the implant was increased, ranging from 7 to 45 mmHg. There was a decrease in these gradients during follow up and in only four of the twelve animals the gradients were above 20 mmHg. Thrombus formation occurred in the prosthesis of six animals, and this was the most frequent complication. CONCLUSION These findings highlight the need for studies with the use of anticoagulants and antiplatelet, an attempt to reduce this event. The study aims to contribute for the start of the use of prosthetic heart valves that could be implanted through minimally invasive techniques without the use of cardiopulmonary bypass.
منابع مشابه
Novel self-expandable, stent-based transcatheter pulmonic valve: a preclinical animal study.
BACKGROUND Because transcatheter implantation of pulmonary valve is indicated for limited-size dysfunctional right ventricular outflow tract only as a balloon-expandable stent, we investigated the feasibility of a large-diameter self-expandable valved stent and the durability of the valve after >6 months. METHODS We made a nitinol-wire-based, self-expandable valved stent with leaflets made fr...
متن کاملTricuspid valved stent implantation: novel stent with a self-expandable super-absorbent polymer.
OBJECTIVE Trans-catheter aortic and pulmonary valve replacement procedures can result in favorable outcomes in selected patients. The aim of this study was to investigate the functioning of a novel self-expanding valved stent with super-absorbent polymer (SAP) for minimally invasive replacement of the tricuspid valve. METHODS A newly designed nitinol stent with SAP was specially designed for ...
متن کاملIncreased Pacemaker Implantation Rate After New-Generation Balloon-Expandable SAPIEN 3 Valve: Who Was to Blame, the Valve or the Doctor?
SEE PAGE 805 T he occurrence of conduction disturbances and the need for permanent pacemaker implantation remain a significant issue associated with transcatheter aortic valve replacement (TAVR) (1). Indeed, the contiguity of the conduction system to the aortic annulus (landing zone of transcatheter valve prostheses) makes this procedure likely to develop this complication (2). To date, several...
متن کاملOff-bypass implantation of a self-expandable valved stent between inferior vena cava and right atrium.
A glutaraldehyde preserved valved bovine jugular xenograft mounted in a nitinol 'Z' stent, expandable from 7 to 28 mm of internal diameter, was evaluated in vitro (column of water developing a pressure of 45 mmHg and a mock loop including a pulsatile pump) and in vivo in five adult pigs with intra-vascular ultrasound to measure the inferior vena cava diameter via a retroperitoneal access. Throu...
متن کاملBalloon-expanding stent and delivery system for transcatheter aortic valve implantation: An animal study
OBJECTIVE To evaluate the feasibility and satefy of transcatheter aortic valve implantation in animals by using a new balloon-expanding valved stent. METHODS The balloon-expandable stent is made from cobalt-based alloy material and designed with a tubular, slotted structure. Fresh bovine pericardium was treated, sutured and fixed on the balloon-expandable stent. Ten healthy sheep (five males ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Revista brasileira de cirurgia cardiovascular : orgao oficial da Sociedade Brasileira de Cirurgia Cardiovascular
دوره 26 3 شماره
صفحات -
تاریخ انتشار 2011