Instrumentation and methodology for simultaneous excitation/detection of ions in an FTICR mass spectrometer
نویسندگان
چکیده
A method for direct and continuous detection of ion motion during different perturbation events of the fourier transform ion cyclotron resonance (FTICR) experiment is demonstrated. The modifications necessary to convert an ordinary FTICR cell into one capable of performing simultaneous excitation/detection (SED) using a capacitive network are outlined. With these modifications, a 200-fold reduction in the detection of the coupled excitation signal is achieved. This allows the unique ability not only to observe the response to the perturbation but to observe the perturbation event itself. SED is used successfully to monitor the ion cyclotron transient during single-frequency excitation, remeasurement and exciter-excite experiments.
منابع مشابه
ESI-FTICR mass spectrometry employing data-dependent external ion selection and accumulation.
Data-dependent external m/z selection and accumulation of ions is demonstrated in use with ESI-FTICR instrumentation, with two different methods for ion selection being explored. One method uses RF/DC quadrupole filtering and is described in use with an 11.5 tesla (T) FTICR instrument, while the second method employs RF-only resonance dipolar excitation selection and is described in use with a ...
متن کاملCollision cross sectional areas from analysis of Fourier transform ion cyclotron resonance line width: a new method for characterizing molecular structure.
We demonstrate a technique for determining molecular collision cross sections via measuring the variation of Fourier transform ion cyclotron resonance (FTICR) line width with background damping gas pressure, under conditions where the length of the FTICR transient is pressure limited. Key features of our method include monoisotopic isolation of ions, the pulsed introduction of damping gas to a ...
متن کاملDesign, Construction and Calibration of a Laser Ionization Time-of-Flight Mass Spectrometer
A time-of-flight mass spectrometer (TOF-MS) developed in our laboratory at Isfahan University of Technology is described here. The TOF-MS instrument uses laser as the ionization source which provides an opportunity to investigate the ions formed in laser ablation or desorption. The TOF-MS has an ionization chamber containing an accelerator and an ion lens to focus the ions into a one meter line...
متن کاملProbing trapped ion energies via ion-molecule reaction kinetics: Fourier transform ion cyclotron resonance mass spectrometry.
The kinetic energy-dependent Ar(+)+ N2 ion-molecule reaction has been used as a chemical "thermometer" to determine the kinetic energy of ions produced by electron ionization and trapped by using a Fourier transform ion cyclotron resonance (FTICR) mass spectrometer. The rate constant for this reaction obtained on the FTICR mass spectrometer was compared to previous work, which allowed a kinetic...
متن کاملInstrumentation for negative ion detection.
The instrumentation and practical circuitry required for the detection of negative ions exiting the mass analysis section of a mass spectrometer is examined. The potentials needed to bias the electron multiplier when detecting negative ions from a low ion-energy mass spectrometer, e.g., a quadrupole, are contrasted with the biasing requirements of a mass spectrometer having high ion-energies, e...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical chemistry
دوره 72 15 شماره
صفحات -
تاریخ انتشار 2000