Coded aperture Raman spectroscopy for quantitative measurements of ethanol in a tissue phantom.

نویسندگان

  • S T McCain
  • M E Gehm
  • Y Wang
  • N P Pitsianis
  • D J Brady
چکیده

Coded aperture spectroscopy allows for sources of large étendue to be efficiently coupled into dispersive spectrometers by replacing the traditional input slit with a patterned mask. We describe a coded aperture spectrometer optimized for Raman spectroscopy of diffuse sources, (e.g., tissue). We provide design details of the Raman system, along with quantitative estimation results for ethanol at non-toxic levels in a lipid tissue phantom. With 60 mW of excitation power at 808 nm, leave-one-out and blind cross-validation of partial least squares (PLS) regression models achieve r(2) > 0.98. Leave-one-out cross-validation demonstrates prediction errors of <15% at the common legal limit for intoxication (17.4 mmol/L = 0.08% by vol) and the best blind cross-validation achieves <12% error at this concentration.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multimodal, multiplex, Raman spectroscopy of alcohol in diffuse, fluorescent media

Optical diagnostics in biological materials are hindered by fluorescence and scattering. We have developed a multimodal, multiplex, coded-aperture Raman spectrometer to detect alcohol in a lipid tissue phantom solution.

متن کامل

Standoff raman spectroscopy system for remote chemical detection

We have developed a class of aperture coding schemes for Remote Raman Spectrometers (RRS) that remove the traditional trade-off between throughput and spectral resolution. As a result, the size of the remote interrogation region can be driven by operational, rather than optical considerations. In this paper we present the design of our coded-aperture standoff spectroscopy system as well as expe...

متن کامل

In Vitro Study of Coded Transmission in Synthetic Aperture Ultrasound Imaging Systems

In the paper the study of synthetic transmit aperture method applying the Golay coded transmission for medical ultrasound imaging is presented. Longer coded excitation allows to increase the total energy of the transmitted signal without increasing the peak pressure. Moreover signal-to-noise ratio and penetration depth are improved while maintaining high ultrasound image resolution. In the work...

متن کامل

Detection and Characterization of Human Teeth Caries Using 2D Correlation Raman Spectroscopy

Background: Carious lesions are formed by a complex process of chemical interaction between dental enamel and its environment. They can cause cavities and pain, and are expensive to fix. It is hard to characterize in vivo as a result of environment factors and remineralization by ions in the oral cavity. Objectives: The development of a technique that gives early diagnosis which is non-invasi...

متن کامل

Multimodal multiplex Raman spectroscopy optimized for in vivo chemometrics

We have designed and constructed a multimodal multiplex Raman spectrometer which uses multi-wavelength excitation to better detect signals in the presence of fluorescence by taking advantage of the shift-variance of the Raman signal with respect to excitation frequency. Coupled with partial-least-squares (PLS) regression, the technique applied to ethanol estimation in a tissue phantom achieves ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied spectroscopy

دوره 60 6  شماره 

صفحات  -

تاریخ انتشار 2006