Using performance reference compound-corrected polyethylene passive samplers and caged bivalves to measure hydrophobic contaminants of concern in urban coastal seawaters.

نویسندگان

  • Abigail S Joyce
  • Mallory S Pirogovsky
  • Rachel G Adams
  • Wenjian Lao
  • David Tsukada
  • Curtis L Cash
  • James F Haw
  • Keith A Maruya
چکیده

Low-density polyethylene (PE) passive samplers containing performance reference compounds (PRCs) were deployed at multiple depths in two urban coastal marine locations to estimate dissolved concentrations of hydrophobic organic contaminants (HOCs), including dichlorodiphenyltrichloroethane (DDT) and its metabolites, polychlorinated biphenyl (PCB) congeners, and polybrominated flame retardants. PE samplers pre-loaded with PRCs were deployed at the surface, mid-column, and near bottom at sites representing the nearshore continental shelf off southern California (Santa Monica Bay, USA) and a mega commercial port (Los Angeles Harbor). After correcting for fractional equilibration using PRCs, concentrations ranged up to 100 pg L(-1) for PCBs and polybrominated diphenyl ethers (PBDEs), 500 pg L(-1) for DDMU and 300 pg L(-1) for DDNU, and to 1000 pg L(-1) for p,p'-DDE. Seawater concentrations of DDTs and PCBs increased with depth, suggesting that bed sediments serve as the source of water column HOCs in Santa Monica Bay. In contrast, no discernable pattern between surface and near-bottom concentrations in Los Angeles Harbor was observed, which were also several-fold lower (DDTs: 45-300 pg L(-1), PCBs: 5-50 pg L(-1)) than those in Santa Monica Bay (DDTs: 2-1100 pg L(-1), PCBs: 2-250 pg L(-1)). Accumulation by mussels co-deployed with the PE samplers at select sites was strongly correlated with PE-estimated seawater concentrations, providing further evidence that these samplers are a viable alternative for monitoring of HOC exposure. Fractional equilibration observed with the PRCs increased with decreasing PRC molar volume indicating the importance of target compound physicochemical properties when estimating water column concentrations using passive samplers in situ.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Near-surface distribution of pollutants in coastal waters as assessed by novel polyethylene passive samplers.

We report a novel and inexpensive method to provide high resolution vertical measurements of temporally integrated organic contaminants in surface and sub-surface waters in polluted coastal environments. It employs a strip of polyethylene deployed as a passive sampler. Verifications are confirmed via conventional spot sample analyses and against Performance Reference Compound (PRC) calibration ...

متن کامل

Application of passive sampling for measuring dissolved concentrations of organic contaminants in the water column at three marine superfund sites.

Currently, there is an effort under way to encourage remedial project managers at contaminated sites to use passive sampling to collect freely dissolved concentrations (Cfree ) of hydrophobic organic contaminants to improve site assessments. The objective of the present study was to evaluate the use of passive sampling for measuring water column Cfree for several hydrophobic organic contaminant...

متن کامل

Polyethylene Passive Samplers for Measuring Hydrophobic Organic Chemical Concentrations in Sediment Porewaters

In order to determine the hazards posed by hydrophobic organic compounds (HOCs) in sediment beds, the following areas of research were explored: (1) the use of polyethylene (PE) sheets as passive sampling devices in sediments, using performance reference compounds (PRCs) in order to reduce deployment times to the order of days, (2) the use of limited PRC data to calibrate mass-transfer models f...

متن کامل

Short-term exposure testing of six different passive samplers for the monitoring of hydrophobic contaminants in water.

Passive sampling devices are increasingly relied upon for monitoring non-polar organic contaminants in water. While many types of devices are available they have seldom been evaluated alongside each other. We tested six passive sampling devices namely: Chemcatcher, two modified versions of the membrane enclosed sorptive coating (MESCO I (m) and MESCO II), silicone rod and strip and semipermeabl...

متن کامل

The Mussel Watch California pilot study on contaminants of emerging concern (CECs): synthesis and next steps.

A multiagency pilot study on mussels (Mytilus spp.) collected at 68 stations in California revealed that 98% of targeted contaminants of emerging concern (CECs) were infrequently detectable at concentrations ≤ 1 ng/g. Selected chemicals found in commercial and consumer products were more frequently detected at mean concentrations up to 470 ng/g dry wt. The number of CECs detected and their conc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chemosphere

دوره 127  شماره 

صفحات  -

تاریخ انتشار 2015