Inter-Observer and Intra-Observer Variability In the Assessment of The Paranasal Sinuses Radiographs

نویسندگان

  • A Norie
  • R Ahmad
  • W Liew
  • M Zahiah
چکیده

The aims of this study are to determine the intra-observer and inter-observer agreement between the two radiologists when reporting the Waters view and 3 views series of the paranasal sinus radiographs. To also determine whether a single Waters view is adequate for diagnostic purpose of sinusitis. 90 sets of paranasal sinuses radiographs were reported by two radiologists independently. The results revealed that the intra-observer and inter-observer agreement varied from almost perfect to good for maxillary and frontal sinuses, but poor for sphenoid and ethmoidal sinuses. Therefore, a single waters view is an acceptable strategy for diagnosing sinusitis for the maxillary and/or frontal sinuses but not for the ethmoid and sphenoid sinuses.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Double and Single Leg Weight-Bearing Radiography in Determining Knee Alignment

  Background: Knee malalignment is an important modifiable cause of osteoarthritis (OA). Surgical therapeutic procedures depend on proper knee alignment assessment. The purpose of this study was to compare knee alignment parameters between double and single leg weight-bearing radiographs and to evaluate the reproducibility of inter- and intra-observer measurements. Methods: One hundred eight p...

متن کامل

Inter-observer agreement between 2-dimensional CT versus 3-dimensional I-Space model in the Diagnosis of Occult Scaphoid Fractures

  Background: The I-Space is a radiological imaging system in which Computed Tomography (CT)-scans can be evaluated as a three dimensional hologram. The aim of this study is to analyze the value of virtual reality (I-Space) in diagnosing acute occult scaphoid fractures.   Methods: A convenient cohort of 24 patients with a CT-scan from prior studies, without a scaphoid fracture on radiograph, ye...

متن کامل

ارزیابی دقت نرم افزار کنتراست معکوس در رادیوگرافی دیجیتال جهت تشخیص شکستگی عمودی ریشه دندان (in vitro)

  Background and Aims: Diagnosis of vertical root fractures often poses a clinical dilemma. Diagnosis of VRF in intraoral radiographs, except in cases where the beam is perpendicular to the direction of fracture is difficult. Misdiagnosis often leads to wrong decisions about the design of teeth future treatment plan. The aim of this study was to determine the diagnostic accuracy of reverse cont...

متن کامل

Evaluation of Intra- and Inter-observer Measurement Variability of a Radiographic Stifle Osteoarthritis Scoring System in Dogs.

Objectives To evaluate the intra- and inter-observer measurement variability of an existing osteoarthritis (OA) stifle scoring system. Methods Paired caudocranial and mediolateral canine stifle radiographs were selected randomly. A total of 15 assessment points were evaluated independently and graded twice (integer numeric scale: 1-4) at an interval of 2 weeks by three observers with different ...

متن کامل

How Well do Orthopedic Surgeons Recognize Different Models of Total Elbow Arthroplasties on Plain Radiographs with the Use of a Diagnostic Flowchart?

Background: Recognition of total elbow arthroplasties (TEAs) on plain radiographs is difficult due to a multitude ofdifferent types and models. Especially if surgery reports and documentation are not available, lost or when the primarysurgery was performed in another hospital the prosthesis type may be undeterminable. Therefore we investigatedin this platform study if a flowch...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2018