Calculation of earthing and screening effects of compensation conductor laid alongside underground multi-cable power lines

نویسندگان

  • I. Medic
  • M. Majstrovic
  • P. Sarajcev
چکیده

Power substations in an urban area are interconnected by high voltage underground power cables, resulting also in interconnections of their earthing grids through cable metallic screens/sheaths. Most modern power cables with XLPE insulated core have metallic screens which are practically insulated from ground. These screens can only be (and usually are) grounded at cable ends and therefore do not act like extra earth electrodes extending from a station. In this case, almost the same positive earthing effects of an extended electrode can be obtained only by extending an auxiliary wire in the same trench and routing it closely parallel to the power line. This bare conductor also provides better screening for nearby telecommunication circuits against inductive interference. This paper presents an analytical method to determine the line-to-ground fault current distribution and related voltages in the earthing system which consists of two substation earthings interconnected by insulated metal sheaths of modern XLPE cables and one bare earthing wire laid in parallel in the same cable trench. The analytical expressions, derived by solving a set of differential equations, are based on the assumption of uniformly distributed conductance between the earthing wire and earth. The proposed mathematical model takes into account mutual inductive couplings between all conductors (phases, cable sheaths and the bare conductor). In addition the paper presents a procedure for computing the resulting nominal screening factor of multi-conductor connection between two substations. The earthing and screening effects of one bare conductor laid parallel to double cable power line are numerically illustrated and outlined. 206 Electrical Engineering and Electromagnetics VI

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electrical and Thermal Analysis of Single Conductor Power Cable Considering the Lead Sheath Effect Based on Finite Element Method

This paper investigates the effect of metallic sheaths on losses and temperature of medium voltage power cables. Two grounding methods of sheaths, including both ends bonding and single point bonding that causes different situations on cable ampacity, are considered. Electrical losses of cables that are main sources of heat are calculated in both conductor and metallic sheath of the cables. She...

متن کامل

HV Substation Earthing Design for Mines

-High Voltage (HV) substation forms important assets for the mining industries. The existences of these substations necessitate earthing design to ensure safety compliance to the mine regulations. The HV system within the mines is consisted of multiple substations which are connected throughout and underground cable. These substations provide the load with the required electrical power to perfo...

متن کامل

Return to Session THE USE OF INSULATED WIRES MILLIKEN CONDUCTORS IN HIGH VOLTAGE POWER TRANSMISSION UNDERGROUND AC LINES

These last years have pointed out a significant increase of the power that needs to be transported by underground power cables. As a consequence, large cross section conductors, up to 2500mm2 are now customarily used. The CIGRE group B1-03 has completed in 2005 a work that analyses the actual AC resistance of these large cross section conductors as a function of their design. The authors discus...

متن کامل

Towards Broadband over Power Lines Sys- Tems Integration: Transmission Character- Istics of Underground Low-voltage Distri- Bution Power Lines

A complete methodology is employed to determine the transmission characteristics of low-voltage/broadband over power lines (LV/BPL) channels associated with underground power distribution networks, in the light of the multiconductor transmission line (MTL) theory. The established bottom-up approach, already used to treat overhead and underground MV/BPL transmission, is extended to analyze BPL t...

متن کامل

Induced Disturbance Voltages in Isolated Conductors Situated in Close Vicinity of a Inducing High Voltage Cable Line

Mutual inductive interferences occur between electrical systems that are located in close vicinity over a certain distance so that the low frequent electromagnetic field can interact between the galvanic isolated systems. Especially in urban regions so-called energy corridors are built where high voltage power lines are often situated close to information and telecommunication lines, other powe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004