Determination of lead and cadmium in ceramicware leach solutions by graphite furnace atomic absorption spectroscopy: method development and interlaboratory trial.
نویسنده
چکیده
This method was developed to improve sensitivity and eliminate time consuming, evaporative pre-concentration in AOAC Method 973.82 and American Society for Testing and Materials method C738 for testing foodware. The method was developed using leach solutions obtained by leaching 9 differently decorated ceramic vessels with 4% acetic acid for 24 h at room temperature. Lead and cadmium concentrations in leach solutions were 0.005-17,600 and 0.0004-0.500 microg/mL, respectively. Concentrations were determined using peak area, phosphate chemical modifier (8.3 microg PO4(-3)), and a standard curve for quantitation. Optimized pre-atomization and atomization temperatures were 1,300 and 1,800 degrees C, respectively, for Pb and 1,100 and 1,700 degrees C, respectively, for Cd. Characteristic masses (mo) were 10 and 0.4 pg for Pb and Cd, respectively. Precision of repeated analyses of calibration solutions was < or =3% relative standard deviation. Precision of duplicate leach solution analyses on different days was 0-9% relative difference. Recovery from fortified leach solutions was 96-106%. Results obtained by this method agreed 92-110% with those of confirmatory analyses. Results of certified reference material solutions agreed 94-100% with certificate values. Pb and Cd limits of quantitation (LOQ) were 0.005 and 0.0005 microg/mL, respectively. Results from 3 trial laboratories for 4 leach solutions containing Pb and Cd concentrations of 0.017-1.47 and <0.0005-0.0864 microg/mL, respectively, agreed 89-102% with results of the author. Two attributes of this method were noteworthy: (1) Background absorbance due to organic matter was entirely absent from atomization profiles, making the use of short pre-atomization hold times (2 s) possible. (2) Instrument precision was excellent and only one determination per solution was needed. Acceptance criteria for quality control measurements and a practical procedure for estimating the method LOQ during routine regulatory analyses are described.
منابع مشابه
GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROMETRY WITH MAlIlRIX MODIFICATION FOR DETERMINATION OF LEAD IN DRINKING WATER
An amoniumvanadate plus sodium molybdate mixed modifier Graphite Furnace Atomic Absorption Spectrometric method has been developed for determination of traces of lead in drinking water. The concentration of lead in the sample is obtained by direct comparison to linear working graph prepared from aqueous standards in the modifier medium, The results indicate the better performance of the pro...
متن کاملInternational Union of Pure and Applied Chemistry Division of Chemistry and the Environment Commission on Oils, Fats and Derivatives * the Determination of Cadmium in Oils and Fats by Direct Graphite Furnace Atomic Absorption Spectrometry
A description is given of the development by collaborative study of a standardised method for the determination of cadmium in crude and refined oils and fats by graphite furnace atomic absorption spectrometry. The procedure is rapid and sensitive allowing determination at levels of 1–10 mg/kg
متن کاملHighly sensitive determination of cadmium and lead in leached solutions from ceramic ware by graphite furnace atomic absorption spectrometry coupled with sequential injection-based solid phase extraction method.
A fully automated pretreatment system based on sequential injection solid-phase extraction (SPE) coupled to a graphite furnace atomic absorption spectrometer (Auto-Pret-GFAAS system) was developed to determine trace amounts of cadmium and lead. A handmade minicolumn packed with a chelating resin was used for the preconcentration of both metals. All protocol for the on-line SPE method was contro...
متن کاملUtilization of electrodeposition on a graphite probe modified with palladium in determination of lead by graphite furnace atomic absorption spectrometry in water and environmental samples
In this work a rapid and selective procedure for separation and preconcentration of lead(Pb2+) before determination by electrothermal atomic absorption spectrometry (ETAAS) wasdeveloped. The procedure is based on the electrodeposition on a graphite probe modified withpalladium. The lead was deposited from acetate buffer solution at pH 5.5. Various parameters,such as pH of solutions, deposition ...
متن کاملMicromethod for lead determination in whole blood by atomic absorption, with use of the graphite furnace.
I describe a micro-scale method for determining lead in whole blood by utilizing a graphite furnace. Sample pretreatment consists of fivefold dilution with a dilute surfactant. The method is directly calibrated with lead standards prepared in dilute HNO3. To eliminate a small, nonspecific absorption signal from the blood matrix, simultaneous background correction is used. Interlaboratory co...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of AOAC International
دوره 84 3 شماره
صفحات -
تاریخ انتشار 2001