Correction of frequency drifts induced by gradient heating in 1H spectra using interleaved reference spectroscopy.
نویسندگان
چکیده
PURPOSE To evaluate the impact of heating-induced frequency drifts on single-voxel spectroscopy and to demonstrate correction strategies based on the interleaved reference scan technique. MATERIALS AND METHODS Frequency drifts induced by gradient heating are assessed for two clinical 3 Tesla (T) whole body MR systems. The interleaved reference scan (IRS) method is used for correcting these frequency drifts in 1H spectra in vitro and in vivo. For severely drift-affected spectroscopy experiments, a feedback-based version of the IRS sequence is proposed, which adds the functionality of a frequency lock to prevent a degradation of the water suppression. RESULTS It is shown that the line widths of the spectral resonances can be largely reduced with the interleaved reference scan method, resulting in considerably improved peak resolution and signal-to-noise ratio. The feedback-based IRS method additionally allows for stable water suppression, even in the presence of very strong frequency drifts. CONCLUSION If spectroscopy scans are combined with imaging scans with a high gradient duty cycle such as diffusion-weighted imaging or functional MRI, a drift correction with IRS can considerably improve the validity of data analysis in research studies.
منابع مشابه
The effect of self-absorption correction using internal reference on determining heavy metals concentration by laser induced breakdown spectroscopy
The identification and concentration of heavy metals, which may be so harmful for the body, is determined by the method of calibration-free laser-induced breakdown spectroscopy using a special strategy. First, the plasma temperature is obtained using the Boltzmann plot. Then, a line with an inappreciable self-absorption is considered for each element as the reference. The modified intensities o...
متن کاملSpectroscopic imaging with prospective motion correction and retrospective phase correction.
Motion-induced artifacts are much harder to recognize in magnetic resonance spectroscopic imaging than in imaging experiments and can therefore lead to erroneous interpretation. A method for prospective motion correction based on an optical tracking system has recently been proposed and has already been successfully applied to single voxel spectroscopy. In this work, the utility of prospective ...
متن کاملCorrection of phase effects produced by eddy currents in solvent suppressed 1H-CSI.
Accurate phasing of MRS spectra is often difficult unless time varying phase effects produced by gradient-induced eddy currents that persist during data acquisition are eliminated. This effect is particularly problematic in 1H-CSI spectra where frequency shifts produced by static field inhomogeneity and phase shifts produced by eddy currents combine. In this paper we present a method that corre...
متن کاملCharacterisation of Motion-Induced Field Distortions in Spectroscopic Imaging With Prospective Motion Correction
Introduction The long scan duration makes spectroscopic imaging (SI) experiments particularly susceptible to motion-induced artifacts. Prospective motion correction based on an optical tracking system [1] has recently been proposed for 2D SI in the human brain [2]. Additionally, retrospective phase correction using the interleaved reference scan (IRS) method has been applied for the correction ...
متن کاملFrequency and phase drift correction of magnetic resonance spectroscopy data by spectral registration in the time domain.
PURPOSE Frequency and phase drifts are a common problem in the acquisition of in vivo magnetic resonance spectroscopy (MRS) data. If not accounted for, frequency and phase drifts will result in artifactual broadening of spectral peaks, distortion of spectral lineshapes, and a reduction in signal-to-noise ratio (SNR). We present herein a new method for estimating and correcting frequency and pha...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of magnetic resonance imaging : JMRI
دوره 33 3 شماره
صفحات -
تاریخ انتشار 2011