Clavicle Kirschner Wire Migration into Left Lung: A Case Report

نویسندگان

  • Érica Lofrano Reghine
  • Caio César Inaco Cirino
  • André Amate Neto
  • Fabiana Rossi Varallo
  • Paulo Roberto Barbosa Évora
  • Tales Rubens de Nadai
چکیده

BACKGROUND Kirschner wires are often used to perform osteosynthesis. Migration through tissue of these wires is a rare but well-known occurrence. CASE REPORT A 65-year-old female presented with light intensity pain complaints in the upper left chest area; personal history included left clavicle fracture 20 years ago that was treated surgically with fixation using a K-wire. Chest radiography showed the presence of metallic foreign body in the left pulmonary apex. An exploratory axillary thoracotomy was performed, and the foreign body was extracted by a pneumotomy. CONCLUSIONS To obtain satisfactory results with a K-wire, some peculiarities in their application should be respected. The time from orthopedic surgery of the collarbone to migration into the chest of the metal rod used can vary from one day to nearly 20 years. Although the migration mechanism remains unclear, it is likely that it involves shoulder movements, breathing movements, negative intrathoracic pressure, gravitational force, or local bone resorption. Caution should be exercised when orthopedic pins and wires are used for the fixation of fractures and dislocations of the shoulder girdle. If there is migration of the wire, it should be removed immediately to avoid sudden and fatal complications.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tracheoinnominate artery fistula caused by migration of a Kirschner wire.

Iatrogenic injury is an underreported but potentially devastating complication of orthopedic wire migration. We report a 48-year-old man with a tracheoinnominate artery fistula caused by migration of a Kirschner wire that was inserted for fixation of a left clavicle fracture nine years before. Following surgical removal of the wire and repair of both trachea and innominate artery, the patient r...

متن کامل

Transthoracic migration of a Kirschner wire from the humerus to the abdomen.

Migration of Kirschner wires after fracture fixation is a rare complication. Several cases of intrathoracic migration after humeral or clavicle fixation with this technique have been reported though. We describe an even rarer case where a wire migrated from the proximal humerus to the abdomen perforating the left thoracic cavity and hemidiaphragm. The distal end of the wire was located next to ...

متن کامل

Intraspinal migration of a Kirschner wire as a late complication of acromioclavicular joint repair: a case report.

BACKGROUND Penetrating neck trauma involving foreign bodies is a rare event in European countries. Due to its relatively high mortality rate, the correct management strategy must be initiated from the beginning to prevent fatal complications. In the medical literature, there are only a few cases describing foreign bodies penetrating the cervical spine. Because of its rareness, many trauma cente...

متن کامل

Fixation of fractures of the midshaft of the clavicle with Kirschner wires. Results in 108 patients.

We treated 110 fractures of the middle third of the clavicle in 108 patients aged between 14 and 66 years, by fixation with 2 mm Kirschner wires. The wire was introduced, using an air drill and a telescoping guide, from the medial into the lateral fragment. The medial end of the wire which perforated the anterior cortex of the medial fragment was bent backwards to prevent migration into the lun...

متن کامل

Comparison of clinical results of surgical treatment for unstable distal clavicle fractures by transacromial pins with and without tension band wire.

BACKGROUND An unstable distal clavicle fracture (Neer type II) is an indication that surgical intervention is required. Numerous treatment options have been introduced, but there is no gold standard. METHODS We report on our experience of 29 consecutive cases, between 2002 and 2008, of acute unstable distal clavicle fracture (Neer type II) and operative treatment using transacromial pins with...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 19  شماره 

صفحات  -

تاریخ انتشار 2018