Cyclic fatigue resistance of different continuous rotation and reciprocating endodontic systems.
نویسندگان
چکیده
OBJECTIVE The objective of this study is to compare the cyclic fatigue resistance of nine types of endodontic instruments of nickel-titanium. MATERIALS AND METHODS Five files of 25 mm of length of each group: Reciproc (RC) R25; WaveOne (WO) Primary; Unicone (UC) L25 25/0.06; K3XF 25/0.06; ProTaper Universal F2 (PTF2); ProTaper Next X2 (PTX2); Mtwo 25/0.06; BioRaCe 25/0.06; One Shape L25 25/0.06 were subjected to a cyclic fatigue resistance test on a mechanical apparatus. The mean fracture time was analyzed statistically by one-way analysis of variance and Tukey's honest significant difference post hoc test, with significance set at P< 0.05. CONCLUSION It was observed that the groups PTX2, RC, R25, UC L25 25/0.06, and WO Primary presented greater cyclic fracture resistance than the other groups (P< 0.001).
منابع مشابه
Effect of movement kinematics on the cyclic fatigue resistance of nickel-titanium instruments.
AIM To compare the cyclic fatigue resistance of new generation OneShape and WaveOne instruments when used with different kinematics. METHODOLOGY An artificial canal, made of stainless steel with an inner diameter of 1.5 mm, a 60° angle of curvature and a curvature radius of 3 mm, was used for cyclic fatigue test of new generation OneShape and WaveOne instruments. Groups were as follows (n = 2...
متن کاملIs the reciprocating movement per se able to improve the cyclic fatigue resistance of instruments?
AIM To compare cyclic fatigue resistance of two geometrically similar nickel-titanium instruments, used in conditions similar to clinical use in reciprocating and continuous rotary motion. METHODOLOGY Four groups of eighteen instruments each, Reciproc(®) files sizes ISO 25 and 40 (R25 and R40) and Mtwo(®) files sizes ISO 25 and 40 (M25 and M40), were tested in reciprocating and continuous rot...
متن کاملInfluence of continuous or reciprocating motion on cyclic fatigue resistance of 4 different nickel-titanium rotary instruments.
INTRODUCTION The aim of this study was to evaluate the resistance to flexural fatigue of Reciproc R25 (VDW, Munich, Germany), WaveOne Primary (VDW, Munich, Germany), Mtwo (Sweden & Martina, Padova, Italy), and Twisted File (TF; SybronEndo, Orange, CA) instruments used in continuous rotation or in 2 different reciprocating motions. METHODS A total of 180 nickel-titanium files from 4 brands mar...
متن کاملExtended cyclic fatigue life of F2 ProTaper instruments used in reciprocating movement.
AIM To evaluate the cyclic fatigue fracture resistance of engine-driven F2 ProTaper instruments under reciprocating movement. METHODOLOGY A sample of 30 NiTi ProTaper F2 instruments was used. An artificial canal was made from a stainless steel tube, allowing the instruments to rotate freely. During mechanical testing, different movement kinematics and speeds were used, which resulted in three...
متن کاملInfluence of file motion on cyclic fatigue of new nickel titanium instruments.
AIM The aim of the present study was to compare the resistance to cyclic fatigue of Hyflex® (Coltene-Whaledent, Allstatten, Switzerland) size 40 taper.04 nickel titanium instruments used in continuous rotation versus the use with a reciprocating motion. The null hypothesis was that different file motions had no influence on the lifetime of instruments subjected to a cyclic fatigue test. METHO...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Indian journal of dental research : official publication of Indian Society for Dental Research
دوره 27 3 شماره
صفحات -
تاریخ انتشار 2016