Prospective evaluation of the feasibility, safety, and efficacy of Cocoon Duct Occluder for transcatheter closure of large patent ductus arteriosus: A single-center study with short- and medium-term follow-up results

نویسندگان

  • Santosh Kumar Sinha
  • Mahmadula Razi
  • Rama Niwas Pandey
  • Prakash Kumar
  • Vinay Krishna
  • Mukesh Jitendra Jha
  • Vikas Mishra
  • Mohammad Asif
  • Nasar Abdali
  • Pradyot Tewari
  • Ramesh Thakur
  • Umeshwar Pandey
  • Chandra Mohan Varma
چکیده

OBJECTIVE To evaluate the feasibility, safety, and efficacy of a novel Cocoon Duct Occluder device for the transcatheter closure (TCC) of large patent ductus arteriosus (PDA). METHODS In this prospective, non-randomized study, consecutive patients with large PDA (narrowest diameter: ≥3.5/4.0 mm in symptomatic/asymptomatic patients, respectively), who underwent TCC with Cocoon Duct Occluder at our institute between November, 2012 and June, 2016 were examined. TCC was performed using the standard technique, and devices were antegradely delivered via 6-10F delivery sheaths. Device embolization, residual shunt, hemolysis, left pulmonary artery (LPA) stenosis, procedural and fluoroscopy time, and mortality were assessed. Patients were followed-up by transthoracic echocardiography with color Doppler imaging at 24 h (D1), 1 month (D30), and 6 months (D180) after implantation. RESULTS A total of 57 patients (age: 11.7±2.8 years; weight: 22.3±3.5 kg) were enrolled. The mean narrowest diameter was 7.4±0.7 mm. The PDA closure was successfully performed in each patient. Fluoroscopy and procedural time was 6.7±3.2 min and 23.9±2.7 min, respectively. Postprocedural angiography revealed that 49 (85.9%) patients had immediate and complete closure, whereas 8 (14.1%) had residual shunt. Color Doppler imaging at D1 revealed complete closure in 52 (91.3%) patients. At D30, complete closure was reported in all patients and was maintained at D180. Hemolysis, embolization, obstruction of LPA or descending aorta, and death were not reported till D180. CONCLUSION TCC using Cocoon Duct Occluder is feasible, safe, and effective in the management of patients with large PDA, with excellent results on short- and medium-term follow-up.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

[Transcatheter closure of patent ductus arteriosus using the Amplatzer duct occluder: initial results and mid-term follow-up].

INTRODUCTION AND OBJECTIVES Transcatheter closure of patent ductus arteriosus is a well-established procedure. The aim of this study was to assess the initial and mid-term results of the treatment of PDA with the Amplatzer duct occluder. PATIENTS AND METHODS From October 1999 to December 2001, 30 children underwent transcatheter closure of persistent ductus arteriosus at a mean SD age of 5 4....

متن کامل

Transcatheter Closure of Patent Ductus Arteriosus Using the Amplatzer Duct Occluder: Initial Results and Mid-Term Follow-Up

Received 11 March 2002. Accepted for publication 28 May 2002. Introduction and objectives. Transcatheter closure of patent ductus arteriosus is a well-established procedure. The aim of this study was to assess the initial and midterm results of the treatment of PDA with the Amplatzer duct occluder. Patients and methods. From October 1999 to December 2001, 30 children underwent transcatheter clo...

متن کامل

Catheter closure of moderate- to large-sized patent ductus arteriosus using the new Amplatzer duct occluder: immediate and short-term results.

OBJECTIVES The aim of this study was to assess the immediate and short-term results of anterograde catheter closure of a moderate- to large-sized patent ductus arteriosus (PDA) using the new self-expandable, respositionable Amplatzer duct occluder (ADO) device. BACKGROUND Transcatheter closure of a PDA using devices or coils is technically challenging and may be accompanied by a 38% incidence...

متن کامل

Transcatheter Closure of Persistent Ductus Arteriosus Using the Amplatzer Duct Occluder in Infants

Background: Despite technical improvements over the years, interventional closure of persistent ductus arteriosus in infants remains a challenge. Objectives: To assess safety, efficacy, and follow up results of closure of symptomatic persistent ductus arteriosus in infants using the self-expanding and repositionable Amplatzer device. Setting: Queen Alia Heart Institute (QAHI), a tertiary cardia...

متن کامل

Efficacy and complications of oral ibuprofen and intravenous acetaminophen in closure of patent ductus arteriosus of preterm neonates

Background: Previous studies have considered patent ductus arteriosus (PDA) a common finding in premature infants, leading to complications such as intracranial hemorrhage, necrotizing enterocolitis and pulmonary dysplasia. The aim of this study was to assess and compare the efficacy of oral ibuprofen and intravenous acetaminophen in the closure of arterial duct in premature newborns. We also e...