Full-brain coverage and high-resolution imaging capabilities of passband b-SSFP fMRI at 3T.
نویسندگان
چکیده
Passband balanced-steady-state free precession (b-SSFP) fMRI is a recently developed method that utilizes the passband (flat portion) of the b-SSFP off-resonance response to measure MR signal changes elicited by changes in tissue oxygenation following increases in neuronal activity. Rapid refocusing and short readout durations of b-SSFP, combined with the relatively large flat portion of the b-SSFP off-resonance spectrum allows distortion-free full-brain coverage with only two acquisitions. This allows for high-resolution functional imaging, without the spatial distortion frequently encountered in conventional high-resolution functional images. Finally, the 3D imaging compatibility of the b-SSFP acquisitions permits isotropic-voxel-size high-resolution acquisitions. In this study we address some of the major technical issues involved in obtaining passband b-SSFP-based functional brain images with practical imaging parameters and demonstrate the advantages through breath-holding and visual field mapping experiments.
منابع مشابه
Characterizing physiological noise in the brainstem: passband SSFP vs. GRE-EPI
Introduction. Functional MRI of the brainstem is complicated by: 1) small grey matter nuclei, 2) severe distortions due to susceptibility boundaries and 3) high levels of physiological noise, all of which make conventional GRE-EPI BOLD problematic. SSFP fMRI has the potential to produce high-resolution images with reduced distortions [1-3], and recent work reported reduced physiological noise f...
متن کاملWhole brain high-resolution functional imaging at ultra high magnetic fields: An application to the analysis of resting state networks
Whole-brain functional magnetic resonance imaging (fMRI) allows measuring brain dynamics at all brain regions simultaneously and is widely used in research and clinical neuroscience to observe both stimulus-related and spontaneous neural activity. Ultrahigh magnetic fields (7T and above) allow functional imaging with high contrast-to-noise ratios and improved spatial resolution and specificity ...
متن کاملFMRI using high flip-angle alternating steady state balanced SSFP supported by Monte Carlo studies
Introduction The need exists for a functional MRI (fMRI) technique capable of artifact-free whole brain coverage, with good blood oxygenation level dependent (BOLD) contrast to noise ratio (CNR), and high temporal resolution. Conventional gradient echo (GRE) BOLD fMRI suffers from signal dropout in regions of magnetic field inhomogeneity, limiting coverage, while spin echo fMRI has reduced BOLD...
متن کاملHigh-resolution non-contrast enhanced dark blood brain vessel imaging using a balanced steady state 3D projection reconstruction sequence
INTRODUCTION Balanced SSFP sequences have been used for non-contrast enhanced vessel imaging as blood signal is bright in SSFP images[1,2]. The dual-halfecho 3D Projection Reconstruction (3DPR) sequence has many advantages for SSFP imaging, including its high data acquisition efficiency and its capability to achieve short TEs and TRs [3]. However, as cerebrospinal fluid (CSF) signal is also bri...
متن کاملSignal and noise characteristics of SSFP FMRI: A comparison with GRE at multiple field strengths
Recent work has proposed the use of steady-state free precession (SSFP) as an alternative to the conventional methods for obtaining functional MRI (FMRI) data. The contrast mechanism in SSFP is likely to be related to conventional FMRI signals, but the details of the signal changes may differ in important ways. Functional contrast in SSFP has been proposed to result from several different mecha...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 59 5 شماره
صفحات -
تاریخ انتشار 2008