Multiple breath inert gas washout as a measure of ventilation distribution in children with cystic fibrosis.

نویسندگان

  • P Aurora
  • P Gustafsson
  • A Bush
  • A Lindblad
  • C Oliver
  • C E Wallis
  • J Stocks
چکیده

BACKGROUND Multiple breath inert gas washout (MBW) has been suggested as a tool for detecting early cystic fibrosis (CF) lung disease. A study was undertaken to compare the relative sensitivity of MBW and spirometry for detecting abnormal lung function in school age children with CF and to compare MBW results obtained from healthy children in the UK with those recently reported from Sweden. METHODS Forced expiratory volume in 1 second (FEV1) and maximal expiratory flow when 25% of forced vital capacity remains to be expired (MEF25) were compared with the lung clearance index (LCI) derived from sulphur hexafluoride MBW in 22 children with CF aged 6-16 years and in 33 healthy controls. RESULTS LCI was higher in children with CF than in healthy controls (mean difference 5.1 (95% CI of difference 4.1 to 6.1) and FEV1 and MEF25 z-scores were lower (mean difference -2.3 (95% CI -2.9 to -1.7) and -1.8 (95% CI -2.4 to -1.3), respectively; p<0.001 for all). There was a significant negative correlation between LCI and FEV1 (r2 = 0.62) and MEF25 (r2 = 0.46). However, while normal (> or =-1.96 z-scores) FEV1 and MEF25 results were seen in 11 (50%) and 12 (53%) children with CF, respectively, all but one of these children had an abnormally increased LCI. LCI was repeatable in both groups (within subject CV for three measurements 6% for CF and 5% for healthy children). In healthy subjects LCI was independent of age and virtually identical in the British and Swedish children (mean difference 0.1 (95% CI -0.1 to 0.4), p = 0.38) CONCLUSIONS MBW is reproducible between laboratories, generates normal ranges which are constant over childhood, and is more frequently abnormal than spirometry in children with CF.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of ventilation maldistribution as an early indicator of lung disease in children with cystic fibrosis.

Many children with cystic fibrosis (CF), receiving modern, aggressive CF care, have normal spirometry results. This study aimed to see if homogeneity of ventilation distribution is impaired early in the course of CF lung disease, and if ventilation inhomogeneity is a more frequent finding than abnormal spirometry in children benefiting from modern CF care. The study compared spirometry findings...

متن کامل

Consensus statement on inert gas washout measurement: at the threshold of clinical use.

I nert gas washout tests including single breath washout (SBW) and multiple breath washout (MBW) have been used for several decades across a wide age range spanning from early infancy to late adulthood. In the past, these lung function tests were typically applied in research settings, assessing lung volume and ventilation distribution in order to gain insight into presence, severity and progre...

متن کامل

CYSTIC FIBROSIS Multiple breath inert gas washout as a measure of ventilation distribution in children with cystic fibrosis

Background: Multiple breath inert gas washout (MBW) has been suggested as a tool for detecting early cystic fibrosis (CF) lung disease. A study was undertaken to compare the relative sensitivity of MBW and spirometry for detecting abnormal lung function in school age children with CF and to compare MBW results obtained from healthy children in the UK with those recently reported from Sweden. Me...

متن کامل

A new double-tracer gas single-breath washout to assess early cystic fibrosis lung disease.

In cystic fibrosis (CF), tests for ventilation inhomogeneity are sensitive but not established for clinical routine. We assessed feasibility of a new double-tracer gas single-breath washout (SBW) in school-aged children with CF and control subjects, and compared SBW between groups and with multiple-breath nitrogen washout (MBNW). Three SBW and MBNW were performed in 118 children (66 with CF) us...

متن کامل

Moment ratio analysis of multiple breath nitrogen washout in infants with lung disease.

Measurement of lung volumes at end expiratory level and assessment of ventilation inhomogeneity is important for respiratory management in infants with lung disease. This study compared multiple breath nitrogen washout was compared with body plethysmography to measure functional residual capacity in infants and assessed ventilation inhomogeneity using mean dilution numbers and alveolar based ga...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Thorax

دوره 59 12  شماره 

صفحات  -

تاریخ انتشار 2004