Precision and accuracy of Morgan ventilometers at continuous and sinusoidal flows.

نویسندگان

  • J D Hart
  • R T Withers
  • R C Tucker
چکیده

The P.K. Morgan Mark II Ventilometer comprises a turbine transducer and a control/readout unit, which contains either a VENTX5A or VENTX6A programme. This equipment is used to measure minute ventilation during oxygen consumption tests. The precision and accuracy of six of these devices (a VENTX5A with two turbines, and two VENTX6As each with two different turbines) were examined during continuous and pulsatile flows; accuracy was affected by the syringe rate during the calibration procedure. The reference standard was a 350 l Collins chain-compensated gasometer. At continuous flows, the two VENTX5A devices showed accuracies of 99.5-100.5% over the range 60-160 l.min-1 whereas those for the four VENTX6As were 99.3-102.1% over the range 60-200 l.min-1. The mean accuracies of sinusoidal flows for the VENTX5A ranged between 96.1-101.3% for minute volumes spanning 15-200 l.min-1; comparable data for the VENTX6As were 95.9-98.9%. These mean accuracies improved to 98.1-101.3% for the VENTX5A at measured minute volumes > 80 l.min-1. Omission of the two lowest tidal volumes (1 and 1.5 l) for the VENTX6As narrowed the range of accuracy to 96.9-98.5%. The coefficients of variation for five trials at each minute ventilation were 0-0.2%. We conclude that, while the P.K. Morgan Mark II Ventilometer has excellent precision, its accuracy is dependent on the calibration syringe rate, minute ventilation and program.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The accuracy of dry gas meters at continuous and sinusoidal flows.

Dry gas meters are used in physiology laboratories to measure minute ventilation. The accuracy of these meters must be known since an error, of for instance 5%, affects the subsequent calculations for oxygen consumption by the same amount. Two precalibrated DTM-325 dry gas meters (American Meter Co., Philadelphia, PA, USA) were therefore tested for accuracy against a 350 l Collins chain-compens...

متن کامل

A preconditioned solver for sharp resolution of multiphase flows at all Mach numbers

A preconditioned five-equation two-phase model coupled with an interface sharpening technique is introduced for simulation of a wide range of multiphase flows with both high and low Mach regimes. Harten-Lax-van Leer-Contact (HLLC) Riemann solver is implemented for solving the discretized equations while tangent of hyperbola for interface capturing (THINC) interface sharpening method is applied ...

متن کامل

The effect of boundary conditions on the accuracy and stability of the numerical solution of fluid flows by Lattice-Boltzmann method

The aim of this study is to investigate the effect of boundary conditions on the accuracy and stability of the numerical solution of fluid flows in the context of single relaxation time Lattice Boltzmann method (SRT-LBM). The fluid flows are simulated using regularized, no-slip, Zou-He and bounce back boundary conditions for straight surfaces in a lid driven cavity and the two-dimensional flow ...

متن کامل

Assessment of Turbulent Models in Computation of Strongly Curved Open Channel Flows

Several rigorous turbulent models have been developed in the past years and it can be seen that more research is needed to reach a better understanding of their generality and precision by verifying their applications for distinct hydraulic phenomena; under certain assumptions. This survey evaluates the performance of Standard k-ε, Realizable k-ε, RNG k-ε, k-ω and RSM models in predicting flow ...

متن کامل

Solution of Flow Field Equations and Verification of Cavitation Problem on Spillway of the dam

The main objective of this paper is to formulate a mathematical model for finding flow field and cavitation problem on dam spillways. The Navier-Stokes Equation has been applied for the computation of pressure and velocity field, free water surface profiles and other parameters. Also, for increasing accuracy of the problem, viscosity effect has been considered. Because of internal flows the eff...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The European respiratory journal

دوره 7 4  شماره 

صفحات  -

تاریخ انتشار 1994