MCNP4C-based Monte Carlo study of grid performance in diagnostic radiology

نویسندگان

  • P. Ghaffarian
  • A. A. Sharafi
  • K. Keshavarz
  • H. Zaidi
چکیده

The MCNP Monte Carlo radiation transport code was used for calculation of scatter distribution and scatter-toprimary ratio (SPR) for different tube voltages, phantom thicknesses and field size in diagnostic radiology. Subsequently, the effect of grid’s design parameters such as strip density, grid ratio, interspace material and lead-tointerspace ratio on scatter rejection was investigated by calculation of bucky factor (BF) and contrast improvement factor (CIF) in more than 120 linear parallel grids under standard conditions proposed by the International Electrotechnical Commission (IEC). The accuracy of simulation of x-ray spectra and photon transport in grids with different design parameters was validated through comparison with measured results demonstrating good agreement, thus increasing the reliability of the results presented in this work.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design of Light Multi-layered Shields for Use in Diagnostic Radiology and Nuclear Medicine via MCNP5 Monte Carlo Code

Introduction Lead-based shields are the most widely used attenuators in X-ray and gamma ray fields. The heavy weight, toxicity and corrosion of lead have led researchers towards the development of non-lead shields. Materials and Methods The purpose of this study was to design multi-layered shields for protection against X-rays and gamma rays in diagnostic radiology and nuclear medicine. In this...

متن کامل

Assessment of the Radiation Attenuation Properties of Several Lead Free Composites by Monte Carlo Simulation

Background:In diagnostic radiology lead apron, are usually used to protect patients and radiology staff against ionizing radiation. Lead apron is a desirable shield due to high absorption and effective attenuation of x-ray photons in the diagnostic radiology range.Objective: Although lead aprons have good radiation protection properties, in recent years, researchers have been looking for altern...

متن کامل

Developement a simple point source model for Elekta SL-25 linear accelerator using MCNP4C Monte Carlo code

Background: Monte Carlo (MC) modeling of a linear accelerator is a prerequisite for Monte Carlo dose calculations in external beam radiotherapy. In this study, a simple and efficient model was developed for Elekta SL-25 linear accelerator using MCNP4C Monte Carlo code Materials and methods: The head of Elekta SL-25 linac was simulated for 6 and 18 MV photon beams using MCNP4C MC code. Energ...

متن کامل

Monte carlo simulation of x-ray spectra in diagnostic radiology and mammography using MCNP4C.

The general purpose Monte Carlo N-particle radiation transport computer code (MCNP4C) was used for the simulation of x-ray spectra in diagnostic radiology and mammography. The electrons were transported until they slow down and stop in the target. Both bremsstrahlung and characteristic x-ray production were considered in this work. We focus on the simulation of various target/filter combination...

متن کامل

Determination of Dosimetric characteristics of a New 192Ir-PDR Brachytherapy Source According to AAPM TG- 43 Protocol using Monte Carlo simulation technique

Introduction: 192Ir is one of the important sources frequently used in brachytherapy. Up to now, a lot of commercial models of this source have been made which Ir-192 has been recently added to them. The aim of the present study is to determine the dosimetric parameters of this new source model based on the recommendations of TG-43(U1) protocol using Monte Carlo simulation tech...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005