Analytical Solution for Speed to Achieve a Desired Operating Point for a given Fan or Pump
نویسندگان
چکیده
The Affinity Laws for fans (and pumps) provide a way of determining new fan or pump speed given fan or pump performance curve data and a desired operating point (combination of flow rate and pressure) that does not fall on the curve. However, the affinity law calculations require using a point on the curve (hereafter referred to as the “basic point”) to determine the new speed. Most references regarding the Affinity Laws do not give a clear description of the method for determining the “basic point”, and improper selection of this point can affect the results considerably. This article describes the requirements for the “basic point,” and presents an analytical solution to determine the “basic point” and the desired operating speed for the fan or pump to operate at the desired operating point conditions.
منابع مشابه
Air and Water Flowrate Optimisation for a Fan Coil Unit in Heat Pump Systems
The degradation in efficiency of auxiliary components in heating/cooling systems when operating at part load is frequently reported. Through the use of variable speed components, the supplied capacity can be reduced to match the required load and hence reduce unnecessary energy consumption. However, for fan coil units, difficulties can arise when optimizing fan and pump speeds at part load. Pra...
متن کاملOptimal Trajectory of Flexible Manipulator with Maximum Load Carrying Capacity
In this paper, a new formulation along with numerical solution for the problem of finding a point-to-point trajectory with maximum load carrying capacities for flexible manipulators is proposed. For rigid manipulators, the major limiting factor in determining the Dynamic Load Carrying Capacity (DLCC) is the joint actuator capacity. The flexibility exhibited by light weight robots or by robots o...
متن کاملEfficient Low-Lift Cooling with Radiant Distribution, Thermal Storage, and Variable-Speed Chiller Controls— Part I: Component and Subsystem Models
Component and subsystem models used to evaluate the performance of a low-lift cooling system are described. An air-cooled chiller, a hydronic radiant distribution system, variable-speed control, and peak-shifting controls are modeled. A variable-speed compressor that operates over 20:1 speed range and pressure ratios ranging from one to six is at the heart of the chiller. Condenser fan and chil...
متن کاملModeling and Simulation of Variable Frequency Pump Control Fatigue Test Machine
High-speed maglev train is considered an ideal vehicle in the 21st Century, as an important part of the train, the travel mechanism bears and delivers a variety of vertical and horizontal alternating load in operation, it affects the operation safety of the train directly, so key components of the travel mechanism should under fatigue strength test by fatigue test machine.The paper proposed a v...
متن کاملNumerical and Economic Study of Performance of Centrifugal Pump as Turbine
In this paper, performance of centrifugal pump as turbine (PAT) is investigated numerically. Three different specific speeds are considered and three pumps are designed using diagrams from catalogues and CFturbo V.9 software. Next, models are analyzed by Ansys CFX 16 software and results are compared with those of CFturbo software. Also, a mesh study analysis for one case is performed in order ...
متن کامل